Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
H3-02 0
F7 L1000A
H3-09 H3-05
H3-13 H3-02 H3-10
0 0 2
2
≠0
≠2
1 2 0
Terminal A1/A2 Switching
H3-13
0
H3-10 0
─
Offset for Terminal A1
─
─
H3-16 0
─
Offset for Terminal A2
─
─
H3-17 0
─
Analog Output 1
Terminal FM
H4-01 2
*
H4-01
102
*
*See the description for F4-01
Analog Output 1
Terminal FM Gain
H4-02 100.0% H4-02 100.0%
F7 L1000A
Setting Range
0.0 % to 1000.0 %
-999.9 % to 999.9%
Analog Output 1
Terminal FM Bias
H4-03 0.0% H4-03 0.0%
F7 L1000A
Setting Range
-110 % to 110 %
-999.9 % to 999.9%
Analog Output 2
Terminal AM
H4-04 3
*
H4-04
103
*
*See the description for F4-01.
Analog Output 2
Terminal AM Gain
H4-05 50.0% H4-05 50.0%
Analog Output 2
Terminal AM Bias
H4-06 0.0% H4-06 0.0%
*See the setting range for H4-01 and H4-02
Analog Output 1
Signal Level Selection
H4-07 0 H4-07 0
F7 L1000A
H4-07 H4-07
0: 0 to +10 V output
0: 0 to +10 Vdc output
1: 0 to ±10 Vdc output
1: 0 to ±10 Vdc output
Multi-Function
Anal
og Ou
tpu
t
Analog Output 2
Signal Level Selection
H4-08 0 H4-08 0
F7 L1000A
H4-08
H4-08
0: 0 to +10 V output
0: 0 to +10 Vdc output
1: 0 to ±10 Vdc output
1: 0 to ±10 Vdc output
Slave Address
H5-01
1F
H5-01
1
─
MEMOBUS
Communica
tion
Communication Speed
Selection
H5-02 3 H5-02 3
F7 L1000A
H5-02 H5-02
0: 1200 bps
0: 1200 bps
1: 2400 bps
1: 2400 bps
2: 4800 bps
2: 4800 bps
3: 9600 bps
3: 9600 bps
4: 19200 bps
4: 19200 bps
─ 5:
38400
bps
─ 6:
57600
bps
─ 7:
76800
bps
─
8: 115200 bps
Communication Parity
Selection
H5-03 0 H5-03 0
F7 L1000A
H5-03 H5-03
0: No parity
0: No parity
1: Even parity
1: Even parity
2: Odd parity
2: Odd parity