Yaskawa F7 to L1000A User Manual
Page 27
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 27 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Timer Function On-Delay
Time
b4-01
0.0 s
b4-01
0.0 s
─
Timers
Timer Function Off-Delay
Time
b4-02
0.0 s
b4-02
0.0 s
─
PID Cntrol Method Selection
b5-01
0
─
─
Proportional Gain Setting (P)
b5-02
1.00
─
─
Integral Time Setting (I)
b5-03
1.0 s
─
─
Integral Limit Setting
b5-04
100.0%
─
─
Derivative Time (D)
b5-05
0.00 s
─
─
PID Output Limit
b5-06
100.0%
─
─
PID Offset Tuning
b5-07
0.0%
─
─
PID Primary Delay Time
b5-08
0.00 s
─
─
PID Output Characteristics
Selection
b5-09 0 ─
─
PID Output Gain Setting
b5-10
1.0
─
─
PI
D Con
trol
PID Output Reverse Selection
b5-11
0
─
─
No corresponding parameter in L1000A.
Selection of PID Feedback
Command Loss Detection
b5-12 0 ─
─
PID Feedback Loss Detection
Level
b5-13 0% ─
─
PID Feedback Loss Detection
Time
b5-14 1.0
s
─
─
PID Sleep Function Start
Level
b5-15 0.0
Hz
─
─
PID Sleep Delay Time
b5-16
0.0 s
─
─
PI
D Con
trol
PID Accel/Decel Time
b5-17
0.0 s
─
─
No corresponding parameter in L1000A.
Dwell Reference at Start
b6-01 0.0
Hz b6-01* 0.0
%
F7 L1000A
Setting Range
0.0Hz to 400.0Hz
0.0% to 100.0%
Dwell Time at Start
b6-02
0.0 s
b6-02
0.0 s
Dwell Frequency at Stop
b6-03 0.0
Hz b6-03* 0.0
%
Dwell Fun
ction
Dwell Time at Stop
b6-04
0.0 s
b6-04
0.0 s
─
Droop Control Gain
b7-01
0.0%
b7-01
0.0%
─
Droop
Con
trol
Droop Control Delay Time
b7-02
0.05 s
b7-02
0.05 s
─
Energy Saving Control
Selection
b8-01 0 b8-01 0
F7 L1000A
b8-01 b8-01
0: Energy Saving disabled 0: Energy Saving disabled
1: Energy Saving enabled 1: Energy Saving enabled
Energy Saving Gain
b8-02
0.7
─
─
Energy Saving Control Filter
Time Constant
b8-03 * ─
─
Energy Saving Coefficient
Value
b8-04 * ─
─
Power Detection Filter Time
b8-05
20 ms
─
─
No corresponding parameter in L1000A.
Energy Sa
ving
Con
trol
Energy Saving Control
Constant
(Ki)
─
─
b8-16*
0.10
For IPM motors only