Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Output Current Error (SE3)
Detection Delay Time
─
─
S6-04
200
ms
─
Brake Response Error (SE4)
Detection Time
─
─
S6-05
500
ms
─
Overacceleration Detection
Level
─
─
S6-10
*
Default setting determined by o1-03 display units.
Overacceleration Detection
Time
─
─
S6-11
50
ms
─
Overacceleration Detection
Selection
─
─
S6-12 0
L1000A
S6-12
0: Always Enabled
1: During run only
Speed Reference Loss
Detection
─
─
S6-15 1
L1000A
S6-15
0: FrL Disabled
1: FrL Enabled
Restart after Baseblock
Selection
─
─
S6-16 0
L1000A
S6-16
0: No Restart
1: Restart