beautypg.com

Yaskawa F7 to L1000A User Manual

Page 32

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 32 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Main Speed Reference Lower
Limit Value

d2-03 0.0%

No corresponding parameter in L1000A.

Jump Frequency 1

d3-01

0.0 Hz

No corresponding parameter in L1000A.

Jump Freq

uency

Jump Frequency 2

d3-02

0.0 Hz

No corresponding parameter in L1000A.

Jump Frequency 3

d3-03

0.0 Hz

Jump Frequency Width

d3-04

1.0 Hz

No corresponding parameter in L1000A.

Frequency

Ref

eren

ce Hold Frequency Reference Hold

Function Selection

d4-01 0 ─

No corresponding parameter in L1000A.

+/-Speed Limit

d4-02 10%

No corresponding parameter in L1000A.

Torque Con

trol

Torque Control Selection

d5-01

0

No corresponding parameter in L1000A.

Torque Reference Delay

Time

d5-02 0

ms

No corresponding parameter in L1000A.

Speed Limit Selection

d5-03

1

Speed Limit

d5-04

0%

Speed Limit Bias

d5-05

10%

Speed/Torque Control
Switchover Timer

d5-06 0

ms

No corresponding parameter in L1000A.

Magneti

c Field

Con

trol

Field Weakening Level

d6-01

80%

No corresponding parameter in L1000A.

Magneti

c

Field Contr

ol

Field Frequency

d6-02

0.0 Hz

No corresponding parameter in L1000A.