Yaskawa F7 to L1000A User Manual
Page 32
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 32 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Main Speed Reference Lower
Limit Value
d2-03 0.0%
─
─
No corresponding parameter in L1000A.
Jump Frequency 1
d3-01
0.0 Hz
─
─
No corresponding parameter in L1000A.
Jump Freq
uency
Jump Frequency 2
d3-02
0.0 Hz
─
─
No corresponding parameter in L1000A.
Jump Frequency 3
d3-03
0.0 Hz
─
─
Jump Frequency Width
d3-04
1.0 Hz
─
─
No corresponding parameter in L1000A.
Frequency
Ref
eren
ce Hold Frequency Reference Hold
Function Selection
d4-01 0 ─
─
No corresponding parameter in L1000A.
+/-Speed Limit
d4-02 10%
─
─
No corresponding parameter in L1000A.
Torque Con
trol
Torque Control Selection
d5-01
0
─
─
No corresponding parameter in L1000A.
Torque Reference Delay
Time
d5-02 0
ms
─
─
No corresponding parameter in L1000A.
Speed Limit Selection
d5-03
1
─
─
Speed Limit
d5-04
0%
─
─
Speed Limit Bias
d5-05
10%
─
─
Speed/Torque Control
Switchover Timer
d5-06 0
ms
─
─
No corresponding parameter in L1000A.
Magneti
c Field
Con
trol
Field Weakening Level
d6-01
80%
─
─
No corresponding parameter in L1000A.
Magneti
c
Field Contr
ol
Field Frequency
d6-02
0.0 Hz
─
─
No corresponding parameter in L1000A.