Yaskawa F7 to L1000A User Manual
Page 40
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 40 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Digi
tal Inpu
ts
Terminal S5 Function
Selection
H1-03
3 (0)
H1-05*
3 (51)
Terminal S6 Function
Selection
H1-04
4 (3)
H1-06*
4 (53)
F7 L1000A
H1-01 to H1-06
H1-03 to H1-08
F: Not used
F: Not used
10: Up command
─
11: Down command
─
12: FWD jog
─
13: REV jog
─
14: Fault Reset
14: Fault Reset
15: Fast Stop (N.O.)
15: Fast Stop (N.O.)
16: Motor switch command 16: Motor switch command
17: Fast Stop (N.C.)
17: Fast Stop (N.C.)
18: Timer function input
18: Timer function input
19: PID control cancel
─
1A: Accel/decel time
selection 2
1A: Accel/decel time
selection 2
1B: Write allowed
─
1C: +Speed Command
─
1D: -Speed Command
─
1E: Analog freq ref sample /
hold
─
20: External fault (N.O.,
Always detected, Ramp to
stop)
20: External fault (N.O.,
Always detected, Ramp to
stop)
21: External fault (N.C.,
Always detected, Ramp to
stop)
21: External fault (N.C.,
Always detected, Ramp to
stop)
22: External fault (N.O.,
Detected during run, Ramp
to stop)
22: External fault (N.O.,
Detected during run, Ramp
to stop)
23: External fault (N.C.,
Detected during run, Ramp
to stop)
23: External fault (N.C.,
Detected during run, Ramp
to stop)
24: External fault (N.O.,
Always detected, Coast to
stop)
24: External fault (N.O.,
Always detected, Coast to
stop)