Yaskawa F7 to L1000A User Manual
Page 31
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 31 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Frequency Reference 8
d1-08
0.00 Hz
d1-08*
0.00 %
Frequency Reference 9
d1-09
0.00 Hz
─
─
Frequency Reference 10
d1-10
0.00 Hz
─
─
Frequency Reference 11
d1-11
0.00 Hz
─
─
Frequency Reference 12
d1-12
0.00 Hz
─
─
Frequency Reference 13
d1-13
0.00 Hz
─
─
Frequency Reference 14
d1-14
0.00 Hz
─
─
Frequency Reference 15
d1-15
0.00 Hz
─
─
Frequency Reference 16
d1-16
0.00 Hz
─
─
Jog Frequency Reference
d1-17
6.00 Hz
─
─
No corresponding parameter in L1000A.
Speed Reference Selection
Mode
─
─
d1-18 0
L1000A
d1-18
0: Use d1-01 to d1-08
1: High Spd Ref Priority (d1-19 to d1-23, d1-26)
2: Leveling Spd Ref Priority (d1-19 to d1-23, d1-26)
3: Use d1-01 to d1-08 No Speed Selection Stops Drive
Nominal Speed
─
─
d1-19
100.0 %
Nominal speed reference when d1-18 = 1 or 2.
Intermediate Speed 1
─
─
d1-20
0.0 %
Intermediate speed reference 1 when d1-18 = 1 or 2.
Intermediate Speed 2
─
─
d1-21
0.0 %
Intermediate speed reference 2 when d1-18 = 1 or 2.
Intermediate Speed 3
─
─
d1-22
0.0 %
Intermediate speed reference 3 when d1-18 = 1 or 2.
Releveling Speed
─
─
d1-23
0.0 %
Re-leveling speed reference when d1-18 = 1 or 2.
Inspection Operation Speed
─
─
d1-24
50.0 %
Speed reference when inspection operation is enabled.
Rescue Operation Speed
─
─
d1-25
10.0 %
Speed reference during inspection operation.
Leveling Speed
─
─
d1-26
8.00 %
Leveling speed reference when d1-18 = 1 or 2.
Frequency Re
feren
ce
Motor 2 Speed Reference
─
─
d1-27*
0.00
Hz
*If set to 0.00, the drive will control motor 1 instead.
*When using motor 2 confirm the accel/decel times are set
in C1-12 and C1-13.
Leveling Speed Detection
Level
─
─
d1-28*
0.00
%
*Used when d1-18 = 0 or 3.
*If the speed reference selected is lower than d1-28, the
drive uses the leveling speed as the active reference.
Leveling
Inspection Speed Det. Level
─
─
d1-29*
0.00
%
* Used when d1-18 = 0 or 3.
If the speed reference selected is higher than d1-28 but
lower or equal to d1-29, the drive uses inspection speed as
the active reference.
Frequency Limits
Frequency Reference Upper
Limit Value
d2-01 100.0%
─
─
No corresponding parameter in L1000A.
Frequency
Limits
Frequency Reference Lower
Limit Value
d2-02 0.0%
─
─
No corresponding parameter in L1000A.