(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 31 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Frequency Reference 8

d1-08

0.00 Hz

d1-08*

0.00 %

Frequency Reference 9

d1-09

0.00 Hz

Frequency Reference 10

d1-10

0.00 Hz

Frequency Reference 11

d1-11

0.00 Hz

Frequency Reference 12

d1-12

0.00 Hz

Frequency Reference 13

d1-13

0.00 Hz

Frequency Reference 14

d1-14

0.00 Hz

Frequency Reference 15

d1-15

0.00 Hz

Frequency Reference 16

d1-16

0.00 Hz

Jog Frequency Reference

d1-17

6.00 Hz

No corresponding parameter in L1000A.

Speed Reference Selection
Mode

d1-18 0

L1000A

d1-18
0: Use d1-01 to d1-08
1: High Spd Ref Priority (d1-19 to d1-23, d1-26)
2: Leveling Spd Ref Priority (d1-19 to d1-23, d1-26)
3: Use d1-01 to d1-08 No Speed Selection Stops Drive

Nominal Speed

d1-19

100.0 %

Nominal speed reference when d1-18 = 1 or 2.

Intermediate Speed 1

d1-20

0.0 %

Intermediate speed reference 1 when d1-18 = 1 or 2.

Intermediate Speed 2

d1-21

0.0 %

Intermediate speed reference 2 when d1-18 = 1 or 2.

Intermediate Speed 3

d1-22

0.0 %

Intermediate speed reference 3 when d1-18 = 1 or 2.

Releveling Speed

d1-23

0.0 %

Re-leveling speed reference when d1-18 = 1 or 2.

Inspection Operation Speed

d1-24

50.0 %

Speed reference when inspection operation is enabled.

Rescue Operation Speed

d1-25

10.0 %

Speed reference during inspection operation.

Leveling Speed

d1-26

8.00 %

Leveling speed reference when d1-18 = 1 or 2.

Frequency Re

feren

ce

Motor 2 Speed Reference

d1-27*

0.00

Hz

*If set to 0.00, the drive will control motor 1 instead.
*When using motor 2 confirm the accel/decel times are set
in C1-12 and C1-13.

Leveling Speed Detection
Level

d1-28*

0.00

%

*Used when d1-18 = 0 or 3.
*If the speed reference selected is lower than d1-28, the
drive uses the leveling speed as the active reference.

Leveling

Inspection Speed Det. Level

d1-29*

0.00

%

* Used when d1-18 = 0 or 3.
If the speed reference selected is higher than d1-28 but
lower or equal to d1-29, the drive uses inspection speed as
the active reference.

Frequency Limits

Frequency Reference Upper
Limit Value

d2-01 100.0%

No corresponding parameter in L1000A.

Frequency

Limits

Frequency Reference Lower
Limit Value

d2-02 0.0%

No corresponding parameter in L1000A.