(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 47 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Stopping Method After
Communication Error

H5-04 3 H5-04 3

F7 L1000A

H5-04 H5-04
0: Ramp to stop

0: Ramp to stop

1: Coast to stop

1: Coast to stop

2: Fast Stop

2: Fast Stop

3: Continue operation

3: Continue operation

Communication Error
Detection Selection

H5-05 1 H5-05 1

F7 L1000A

H5-05 H5-05
0: Disabled

0: Disabled

1: Enabled

1: Enabled

Send Wait Time

H5-06

5ms

H5-06

5ms

RTS Control Selection

H5-07

1

H5-07

1

F7 L1000A

H5-07 H5-07
0: Disabled
(RTS always on)

0: Disabled
(RTS always on)

1: Enabled
(RTS enabled during send
only)

1: Enabled
(RTS enabled during send
only)

CE Detection Time

H5-09

2.0

s

Unit Selection for MEMOBUS
Register 0025H

H5-10 0 H5-10 0

F7 L1000A

H5-10 H5-10
0: 0.1 V units

0: 0.1 V units

1: 1 V units

1: 1 V units

MEMOBU

S C

ommunic

at

ion

Communications ENTER
Function Selection

H5-11 0

L1000A

H5-11
0: Enter Cmd Req.
1: Enter Cmd Not Req.

Pulse Train Input Function
Selection

H6-01 0 ─

Pulse Train Input Scaling

H6-02

1440 Hz

Pulse Train Input Gain

H6-03

100.0%

Pulse Train Input Bias

H6-04

0.0%

Pulse Train Input Filter Time

H6-05

0.10 s

No corresponding parameter in L1000A.

Pulse Train Monitor Selection

H6-06

2

No corresponding parameter in L1000A.

P

ul

se T

ra

in I/

O

Pulse Train Monitor Scaling

H6-07

1440 Hz

Motor Overload Protection
Selection

L1-01 1 L1-01 1

*

F7 L1000A

L1-01 L1-01
0: Disabled

0: Disabled

1: General-purpose motor
protection

1: General-purpose motor
protection

2: Drive-dedicated motor
protection

2: Drive-dedicated motor
protection

3: Vector motor protection 3: Vector motor protection

5: PM motor protection
(constant torque)

*Determined by the control mode selected.

Motor Overload Protection
Time

L1-02

8.0min

L1-02

1.0 min.

F7 L1000A

Setting Range
0.1 to 20.0 min

0.1 to 5.0 min

Motor Overheat Alarm
Operation Selection

L1-03 3 ─

Motor Protection

Function

Motor Overheat Fault
Operation Selection

L1-04 1 ─

No corresponding parameter in L1000A.