beautypg.com

Yaskawa F7 to L1000A User Manual

Page 21

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 21 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

Control Circuit Terminal Size and Gauges

Power

Supply

Model

Capacity

Terminal Signal

Terminal Screw

Tightening

Torque

(NM)

Possible

Gauges

(mm

2

)

Recommended

Gauges (mm

2

)

FM, AC, AM, P1, P2, PC,
SC, A1, A2, A3, +V, -V,
S1, S2, S3, S4, S5, S6, S7,
S8,
MA, MB, MC, M1, M2

M3.5

0.8 to 1.0

0.5 to 2.0

0.75

MP, RP, R+, R-, S+, S-, IG

M2

Phoenix

Type

0.5 to 0.6

Stranded wire

0.14 to 1.5

single

conductor

0.14 to 2.5

0.75

200 V Class
400 V Class

F7

All
capacities

E (G)

M3.5

0.8 to 1.0

0.5 to 2.0

1.25

M2

0.22 to 0.25

Stranded wire

0.25 to 1.0

single

conductor

0.25 to 1.5

0.75

200 V Class
400 V Class

L1000A

All
capacities

FM, AC, AM, P1, P2, PC,
SC, A1, A2, +V, -V,
S1, S2, S3, S4, S5, S6, S7,
S8,
MA, MB, MC, M1,M2, M3,
M4, M5, M6
H1, H2, HC, DM+, DM-
IG, R+, R-, S+, S-,
E(G)

M2

Phoenix

Type

0.22 to 0.25

0.25 to 0.5

0.5