Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Stopping Method Selection

b1-03

0

b1-03

0

F7 L1000A

b1-03 b1-03
0: Ramp to stop

0: Ramp to stop

1: Coast to stop

1: Coast to stop

2: DC Injection Braking

3: Coast to stop with timer

Reverse Operation Selection

b1-04

0

Operation Selection for
Setting E1-09 or Less

b1-05 0 ─

No corresponding parameter in L1000A.

Read Sequence Input Twice

b1-06

1

b1-06

1

F7 L1000A

b1-06 b1-06
0: 2 ms - 2 scans

0: 1 ms - 1 scan

1: 5 ms - 2 scans

1: 1 ms - 2 scans

Operation Selection After
Switching to Remote Mode

b1-07 0 ─

No corresponding parameter in L1000A.

Run Command Selection
while in Programming Mode

*Up/Down Command
Selection while in
Programming Mode

b1-08 0 b1-08 0

F7 *L1000A

b1-08 b1-08
0: Disabled.

0: Disabled.

1: Run cmd always
accepted

1: Up/Down always
accepted

2: Cannot enter Program
Mode

2: Cannot enter Program
Mode

Phase Order Selection

b1-14 0

0: U-V-W
1: U-W-V

Zero-speed Level

b2-01

0.5 Hz

DC injection braking current

b2-02

50%

DC Injection Braking Time at
Start

b2-03 0.00

s

DC Injection Braking Time at
Stop

b2-04 0.50

s

No corresponding parameter in L1000A.

DC Inje

ctio

n

Br

akin

g

Magnetic Flux Compensation
Value

b2-08 0% b2-08 0%

Speed Search Selection

b3-01


2


Speed Search Operating
Current

b3-02 150%

Speed Search Deceleration
Time

b3-03 2.0

s

Speed Search Delay Time

b3-05

0.2 s

Sets the Magnetic Flux
Compensation as a
Percentage of the No-load
Current

b3-10 1.10

Rotation Direction Search
Selection

b3-14 1 ─

Speed Search Restart Current
Level

b3-17 150%

Speed Search Restart
Detection Time

b3-18 0.10

s

Speed S

earch

Number of Speed Search
Restarts

b3-19 0 ─