Yaskawa F7 to L1000A User Manual
Page 36
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 36 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Operation Selection at PG
Open Circuit (PGo)
F1-02 1 F1-02 1
F7 L1000A
F1-02 F1-02
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
Operation Selection at
Overspeed (oS)
F1-03 1 F1-03 1
F7 L1000A
F1-03 F1-03
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
Operation Selection at
Deviation
F1-04 3 F1-04 3
F7 L1000A
F1-04 F1-04
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
PG Rotation Selection
F1-05
0
F1-05
0
F7 L1000A
F1-05 F1-05
0: FWD = A pulse leads
0: FWD = A pulse leads
1: FWD = B pulse leads
1: FWD = B pulse leads
PG Division Rate (PG Pulse
Monitor)
F1-06
1
F1-06
1
Enabled when using the PG-B2 option card.
Integral Value During
Accel/Decel Enable/Disable
F1-07 0 ─
─
No corresponding parameter in L1000A.
Overspeed Detection Level
F1-08
115%
F1-08
115%
─
Overspeed Detection Delay
Time
F1-09
1.0 s
F1-09
0.0 s
─
Excessive Speed Deviation
Detection Level
F1-10 10% F1-10 10%
─
Excessive Speed Deviation
Detection Delay Time
F1-11
0.5 s
F1-11
0.5 s
─
Number of PG Gear Teeth 1
F1-12
0
─
─
Number of PG Gear Teeth 2
F1-13
0
─
─
No corresponding parameter in L1000A.
PG Open-Circuit Detection
Time
F1-14
2.0 s
F1-14
2.0 s
─
Dv3 Detection Selection
(CLV/PM)
─
─
F1-18 10
─
Dv4 Detection Selection
(CLV/PM)
─
─
F1-19
128
─
PG speed
Contr
ol Card
PG Option Card
Disconnection Detection 1
─
─
F1-20 1
L1000A
F1-20
0: Disabled
1: Enabled
PG speed
Contr
ol
Card
dEv Detection Condition
Selection
─
─
F1-29 2
L1000A
F1-29
0: After Spd ref, SFS output and motor speed have
matched once.
1: After Spd ref, SFS output has matched once.
2: Always during run
PGoH Detection Level
─
─
F1-51
80%