Parameter Cross Reference

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Language Selection

A1-00

0

A1-00

0

F7 L1000A

A1-00 A1-00
0: English

0: English

1: Japanese

1: Japanese

2: German

2: German

3: French

3: French

4: Italian

4: Italian

5: Spanish

5: Spanish

6: Portuguese

6: Portuguese

─ 7:

Chinese

Access Level Selection

A1-01

2

A1-01

2

F7 L1000A

A1-01 A1-01
0: Operation only
(monitors only)

0: Operation only
(monitors only)

1: User Parameters

1: User Parameters *

2: All parameters

2: All parameters

*Set parameters A2-01 through A2-32.

Control Method Selection

A1-02

2

A1-02

2

F7 L1000A

A1-02 A1-02
0: V/f Control

0: V/f Control

1: V/f w/PG Control

2: Open Loop Vector

2: Open Loop Vector

3: Flux Vector

3: Closed Loop Vector

7: Closed Loop Vector for PM

Initialize Parameters

A1-03

0

A1-03

0

F7 L1000A

A1-03 A1-03
0: No initialization

0: No initialization

1110: User initialize

1110: User initialize

2220: 2-wire sequence

2220: 2-wire sequence

3330: 3-wire sequence

─ 5550:

Reset

OPE04

Password A1-04

0

A1-04

0

Password Setting

A1-05

0

A1-05

0

Environmen

t Se

ttin

gs

User Parameters

A2-01 to

A2-32

A2-01 to

A2-32

*If setting A1-01 to 1, refer to the manual and set parameters
A2-01 to A2-32.

Frequency Reference
Selection

b1-01

1

b1-01

0

F7 L1000A

b1-01 b1-01
0: Operator

0: Operator

1: Control circuit terminal
(analog input)

1: Control circuit terminal
(analog input)

2: MEMOBUS comm.

2: MEMOBUS comm.

3: Option card

3: Option card

4: Pulse train input

Operati

on Mode

Se

lection

Operation Method Selection

*Up/Down Command
Selection

b1-02 1 b1-02 1

F7 *L1000A

b1-02 b1-02
0: Operator

0: Operator

1: Control circuit terminal

1: Control circuit terminal

2: MEMOBUS comm.

2: MEMOBUS comm.

3: Option card