F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Starting Torque
Compensation Bias in Down
Direction

S3-12 0

Torque Compensation Fade
Out Speed

─ S3-14 0.0

%

Torque Compensation Fade
Out Time

S3-15

1000

ms

Torque Limit Reduction Time

S3-16

100

ms

Dwell2 Speed Reference

S3-20

0.00

%

Dwell2 End Speed

S3-21

0.00

%

DC Injection Gain in
Regenerative Operation

S3-25

100.0

%

DC Injection Gain in Motoring
Operation

S3-26

20.0

%

Torque Compensation Value
with Load Condition 1

S3-27

-50.0

%

Torque Compensation Value
with Load Condition 2

S3-28

50.0

%

Analog Input from Load Cell
with Load Condition 1

─ S3-29 0.0

%

Analog Input from Load Cell
with Load Condition 2

S3-30

100.0

%

Used for starting torque compensation utilizing a load cell
signal.

Anti-Rollback Torque Bias 1

─ S3-34 0.0

%

Anti-Rollback Torque Bias 2

─ S3-35 0.0

%

Position Deviation Level to
Apply ARB Torque Bias 1

S3-37 0

Position Deviation Level to
Apply ARB Torque Bias 2

S3-38 0

Anti-Rollback Integral Gain

S3-39

0.00

Sets the responsiveness for Anti-Rollback during Position
Lock.

Anti-Rollback Movement
Detection

S3-40

1

pulse

Sets the amount of pulses for movement detection during
Anti-Rollback.

Star

t/S

top

Op

tim

iz

ation

Position Lock Gain at Start 2
Reduction

S3-41

0.50

Light Load Direction Search
Selection

S4-01 0

L1000A

S4-01

0: Disabled

1: Enabled

2: Enabled Motor 1 only

Light Load Direction Search
Method

S4-02 1

L1000A

S4-02

0: Output Current

1: Regenerative Direction detection

Light Load Direction Search
Time

S4-03

1.0

s

Re

scue

Op

erati

on

Light Load Direction Search
Speed Reference

S4-04

*

*Determined by control method.