Yaskawa F7 to L1000A User Manual
Page 45
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 45 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Terminal A3 Function
Selection
H3-05 2 ─
─
F7 L1000A
H3-05, H3-09
H3-02, H3-10
0: Terminal A1 bias
0: Terminal A1 Bias
1: Frequency gain
─
2: Auxiliary freq ref 1
2: Auxiliary freq ref 1
3: Auxiliary freq ref 2
3: Auxiliary freq ref 2
4: Output voltage bias
─
5: Accel/decel time gain
─
6: DC Injection Braking
current
─
7: Torque detection level
─
8: Stall Prevention level
during run
─
9: Output freq lower limit
level
─
A: Jump frequency
─
B: PID feedback
─
C: PID setpoint
─
D: Frequency bias 2
─
E: Motor temperature input
─
F: Through- mode
─
10: FWD torque limit
─
11: REV torque limit
─
12: Torque limit during
regen
─
13: Torque ref/speed limit
during Torque Control
─
14: Torque compensation
14: Torque compensation
15: P/N both side torque
limit
─
─
─
1F: Not used for analog
input
1F: Not used for analog
input
─
─
Analog Inpu
t
Terminal A3 Gain Setting
H3-06
100.0%
─
─
No corresponding parameter in L1000A.
Terminal A2 Signal Level
Selection
H3-08 2 H3-09 0
F7 L1000A
H3-08 H3-09
0: 0 to 10 V
0: 0 to +10 V
(with lower limit)
1: -10 to 10 V
1: -10 to 10 V
2: 4 to 20 mA
─
Terminal A2 Function
Selection
H3-09 0
*
H3-10
1F*
*For L1000A, see table for A3 Function Selection
Terminal A2 Gain Setting
H3-10
100.0%
H3-11
100.0%
F7 L1000A
Setting Range
0.0 % to 1000.0 %
-999.9 % to 999.9%
Terminal A2 Input Bias
H3-11
0.0%
H3-12
0.0%
F7 L1000A
Setting Range
-100.0 % to 100.0 %
-999.9 % to 999.9%
Analog Input Filter Time
Constant
H3-12
0.03 s
H3-13
0.03 s