Drive Replacement Checklist

Classification

Item

Checklist

Check

Verifying Installation Area of the Drive

Dimensions and installation holes differ between F7 and L1000A.

Verifying the Installation Location of the Digital Operator

When replacing the F7 drive, consider whether the new drive will need to have
the digital operator mounted to the same location or if a different location is
required.

If the same location is important, please consider the mounting position of the
digital operator when installing the new unit.

Drive

Verifying Specialized Specifications
Check to see if the F7 drive has a custom nameplate, or any other custom
specifications.

Verifying Main Circuit Lines (including ground)
When replacing the F7 drive, be aware that the position of the main circuit terminal
block wiring and wiring order will differ with the newer model. Consider how to
rewire the terminal block or if different length cables are required.

Main Circuit

Verifying Main Circuit Terminal Block and Specifications
When replacing the drive, be aware that the position of the terminals may not be the
same shape or size in the newer model. Refer to the terminal layout to ensure a
proper match.

Hardware

Control Circuit

Verifying Control Circuit Wiring
When replacing the F7 drive, be aware that the position of the control circuit
terminal block and wiring order will differ with the newer model. Consider how to
rewire the terminal block or if different length cables are required. Refer to the
terminal layout in the product instructions to ensure a proper match

Software

Verifying Custom Software
Check the drive software you are currently using to see if it is a standard Yaskawa
software. If you’re not sure whether the software is standard or not, confirm the
software number by contacting your Yaskawa representative.

Software

Parameter

Verifying Parameter Settings

Check the parameter settings in the drive you are currently using. Use this
replacement guide to set the new parameters to match the current application.

For specialized software or for parameters not covered in this replacement guide,
contact your Yaskawa representative.

Option &

Other

Option

Card

Verifying Option Cards
Option cards will need to be replaced with new option cards, as L1000A is not
compatible with option cards used in F7 models.