(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 53 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Traction Sheave Diameter

o1-20

400 mm

Scales the display unit calculations.

Roping Ratio

o1-21

2

Sets the ratio (1:1, 1:2, 1:3 or 1:4)

Mechanical Gear Ratio

o1-22

*

Determined by the control method.

LOCAL/REMOTE Key
Function Selection

o2-01

1

o2-01

0

F7 L1000A

o2-01 o2-01

0: Disabled

0: Disabled

1: Enabled

1: Enabled

STOP Key Function Selection

o2-02

1

o2-02

0

F7 L1000A

o2-02 o2-02

0: Disabled

0: Disabled

1: Enabled

1: Enabled

User Parameter Default Value

o2-03

0

o2-03

0

F7 L1000A

o2-03 o2-03

0: No change

0: No change

1: Save values

1: Save values

2: Clear memory

2: Clear memory

Drive Model Selection

o2-04

*

o2-04

*

Do not change this setting.
Determined by drive capacity.

Frequency Reference Setting
Method Selection

o2-05 0 o2-05 0

F7 L1000A

o2-05 o2-05

0: ENTER required

0: ENTER required

1: ENTER key not required 1: ENTER key not required

Operation Selection when
Digital Operator is
Disconnected

o2-06 0 o2-06 0

F7 L1000A

o2-06 o2-06

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Cumulative Operation Time
Setting

o2-07 0H o4-01 0H

Cumulative Operation Time
Selection

o2-08 0 o4-02 0

F7 L1000A

o2-08 o4-02
0: Whenever the power is
on

0: Whenever the power is
on

1: During run only

1: During run only

Factory Tuning

o2-09

0

o2-09

*

*Do not change this setting.

Fan Operation Time
(L1000A: Cooling Fan
Operation Time Setting)

o2-10 0H o4-03 0H

F7 Setting Range : 0 to 65535H
L1000A Setting Range : 0 to 9999H

Fault Trace, Fault History
Reset

o2-12 0 o4-11 0

F7 L1000A

o2-12 o4-11

0: No change

0: No change

1: Reset U2, U3 parameters 1: Reset U2, U3 parameters

Multi-Function

Sele

ctio

n

kWh Monitor Initialize
Selection

o2-14 0 o4-12 0

F7 L1000A

o2-14 o4-12

0: No change

0: No change

1: Reset the kWh monitor

1: Reset the kWh monitor