Yaskawa F7 to L1000A User Manual
Page 53
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 53 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Traction Sheave Diameter
─
─
o1-20
400 mm
Scales the display unit calculations.
Roping Ratio
─
─
o1-21
2
Sets the ratio (1:1, 1:2, 1:3 or 1:4)
Mechanical Gear Ratio
─
─
o1-22
*
Determined by the control method.
LOCAL/REMOTE Key
Function Selection
o2-01
1
o2-01
0
F7 L1000A
o2-01 o2-01
0: Disabled
0: Disabled
1: Enabled
1: Enabled
STOP Key Function Selection
o2-02
1
o2-02
0
F7 L1000A
o2-02 o2-02
0: Disabled
0: Disabled
1: Enabled
1: Enabled
User Parameter Default Value
o2-03
0
o2-03
0
F7 L1000A
o2-03 o2-03
0: No change
0: No change
1: Save values
1: Save values
2: Clear memory
2: Clear memory
Drive Model Selection
o2-04
*
o2-04
*
Do not change this setting.
Determined by drive capacity.
Frequency Reference Setting
Method Selection
o2-05 0 o2-05 0
F7 L1000A
o2-05 o2-05
0: ENTER required
0: ENTER required
1: ENTER key not required 1: ENTER key not required
Operation Selection when
Digital Operator is
Disconnected
o2-06 0 o2-06 0
F7 L1000A
o2-06 o2-06
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Cumulative Operation Time
Setting
o2-07 0H o4-01 0H
─
Cumulative Operation Time
Selection
o2-08 0 o4-02 0
F7 L1000A
o2-08 o4-02
0: Whenever the power is
on
0: Whenever the power is
on
1: During run only
1: During run only
Factory Tuning
o2-09
0
o2-09
*
*Do not change this setting.
Fan Operation Time
(L1000A: Cooling Fan
Operation Time Setting)
o2-10 0H o4-03 0H
F7 Setting Range : 0 to 65535H
L1000A Setting Range : 0 to 9999H
Fault Trace, Fault History
Reset
o2-12 0 o4-11 0
F7 L1000A
o2-12 o4-11
0: No change
0: No change
1: Reset U2, U3 parameters 1: Reset U2, U3 parameters
Multi-Function
Sele
ctio
n
kWh Monitor Initialize
Selection
o2-14 0 o4-12 0
F7 L1000A
o2-14 o4-12
0: No change
0: No change
1: Reset the kWh monitor
1: Reset the kWh monitor