Yaskawa F7 to L1000A User Manual
Page 33
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 33 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Field Forcing Function
Selection
d6-03 0 d6-03 0
F7 L1000A
d6-03 d6-03
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Field Forcing Limit
d6-06
400%
d6-06
400%
─
Input Voltage Setting
E1-01
200 V
*
E1-01 200
V
*
*Double values for 400 V class drives.
V/
f C
harac
terist
ic
s
V/f Pattern Selection
E1-03
F
E1-03
F
F7 L1000A
E1-03 E1-03
0: 50 Hz spec. (constant
torque characteristics 1)
─
1: 60 Hz spec. (constant
torque characteristics 2)
─
2: 60 Hz spec. (constant
torque characteristics 3),,
voltage saturation at 50 Hz
─
3: 72 Hz spec. (constant
torque characteristics 4),
voltage saturation at 60 Hz
─
4: 50 Hz spec.
(derated torque 1)
─
5: 50 Hz spec.
(derated torque 2)
─
6: 60 Hz spec. (derated
torque 3)
─
7: 60 Hz spec.
(derated torque 4)
─
8: 50 Hz spec.
(high starting torque 1)
─
9: 50 Hz spec. (high
starting torque 2)
─
A: 60 Hz spec.
(high starting torque 3)
─
B: 60 Hz spec.
(high starting torque 4)
─
C: 90 Hz spec. , voltage
Saturation at 60 Hz
─
D: 120 Hz spec., voltage
saturation at 60 Hz
─
E: 180 Hz spec., voltage
saturation at 60 Hz
─
F: User-Set V/f pattern
F: User-Set V/f pattern
Max Output Frequency
E1-04
60.0 Hz
*
E1-04 60.0
Hz
*
*Depends on the control mode and the V/f pattern selected.
Max Voltage
E1-05
200.0 V
*
E1-05 200.0
V
*
*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.
Base Frequency
E1-06
60.0 Hz
*
E1-06 60.0
Hz
*
*Depends on the control mode and the V/f pattern selected.
Mid. Output Frequency
E1-07
3.0 Hz
*
E1-07 3.0
Hz
*
*Depends on the control mode and the V/f pattern selected.
Mid. Output Frequency
Voltage
E1-08 15.0
V
*
E1-08 11.0
V
*
*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.
Minimum Output Frequency
E1-09
1.5 Hz
*
E1-09 0.5
Hz
*
*Depends on the control mode and the V/f pattern selected.
Minimum Output Frequency
Voltage
E1-10 9.0
V
*
E1-10 2.0
V
*
*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.
Mid. Output Frequency 2
E1-11
0.0 Hz
E1-11
0.0 Hz
─
V/
f C
harac
terist
ic
s
Mid. Output Frequency
Voltage 2
E1-12
0.0 V
E1-12
0.0 V
─