beautypg.com

Yaskawa F7 to L1000A User Manual

Page 33

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 33 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Field Forcing Function
Selection

d6-03 0 d6-03 0

F7 L1000A

d6-03 d6-03
0: Disabled

0: Disabled

1: Enabled

1: Enabled

Field Forcing Limit

d6-06

400%

d6-06

400%

Input Voltage Setting

E1-01

200 V

*

E1-01 200

V

*

*Double values for 400 V class drives.

V/

f C

harac

terist

ic

s

V/f Pattern Selection

E1-03

F

E1-03

F

F7 L1000A

E1-03 E1-03
0: 50 Hz spec. (constant
torque characteristics 1)

1: 60 Hz spec. (constant
torque characteristics 2)

2: 60 Hz spec. (constant
torque characteristics 3),,
voltage saturation at 50 Hz

3: 72 Hz spec. (constant
torque characteristics 4),
voltage saturation at 60 Hz

4: 50 Hz spec.
(derated torque 1)

5: 50 Hz spec.
(derated torque 2)

6: 60 Hz spec. (derated
torque 3)

7: 60 Hz spec.
(derated torque 4)

8: 50 Hz spec.
(high starting torque 1)

9: 50 Hz spec. (high
starting torque 2)

A: 60 Hz spec.
(high starting torque 3)

B: 60 Hz spec.
(high starting torque 4)

C: 90 Hz spec. , voltage
Saturation at 60 Hz

D: 120 Hz spec., voltage
saturation at 60 Hz

E: 180 Hz spec., voltage
saturation at 60 Hz

F: User-Set V/f pattern

F: User-Set V/f pattern

Max Output Frequency

E1-04

60.0 Hz

*

E1-04 60.0

Hz

*

*Depends on the control mode and the V/f pattern selected.

Max Voltage

E1-05

200.0 V

*

E1-05 200.0

V

*

*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.

Base Frequency

E1-06

60.0 Hz

*

E1-06 60.0

Hz

*

*Depends on the control mode and the V/f pattern selected.

Mid. Output Frequency

E1-07

3.0 Hz

*

E1-07 3.0

Hz

*

*Depends on the control mode and the V/f pattern selected.

Mid. Output Frequency
Voltage

E1-08 15.0

V

*

E1-08 11.0

V

*

*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.

Minimum Output Frequency

E1-09

1.5 Hz

*

E1-09 0.5

Hz

*

*Depends on the control mode and the V/f pattern selected.

Minimum Output Frequency
Voltage

E1-10 9.0

V

*

E1-10 2.0

V

*

*Depends on the control mode and the V/f pattern selected.
Double values for 400 V class drives.

Mid. Output Frequency 2

E1-11

0.0 Hz

E1-11

0.0 Hz

V/

f C

harac

terist

ic

s

Mid. Output Frequency
Voltage 2

E1-12

0.0 V

E1-12

0.0 V