Yaskawa F7 to L1000A User Manual
Page 56
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 56 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Rescue Operation Torque
Limit
─
─
S4-05
100.0
%
─
Rescue Operation Power
Supply Selection
─
─
S4-06 0
L1000A
S4-06
0: Batterry
1: UPS (single-phase)
2: UPS (three-phase)
UPS Power
─
─
S4-07
0.0 kVa
Sets the capacity of the UPS.
UPS Operation Speed Limit
Selection
─
─
S4-08 2
L1000A
S4-08
0: Disabled
1: Enabled until Light Load Detection Search is complete
2: Enabled until stop
DC Bus Voltage During
Rescue Operation
─
─
S4-12 0
V
─
Rescue Operation Power
Supply Deterioration
Detection Level
─
─
S4-13
80.0
%
Determines at which level of backup power supply
deterioration a PF5 fault is triggered.
Short Floor Operation
Selection
─
─
S5-01 0
L1000A
S5-01
0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
Nominal Speed for Short Floor
Calculation
─
─ S5-02 0.0
%
When d1-18 is set for 0 or 3, S5-02 determines the rated
speed used during Short Floor.
Short Floor Minimum
Constant Speed Time
─
─
S5-03
0.0
s
Sets the minimum operation time when Short Floor function
is enabled.
Distance Calculation
Acceleration Time Gain
─
─
S5-04
150.0
%
─
Distance Calculation
Deceleration Time Gain
─
─
S5-05
150.0
%
─
Stopping Method Selection
─
─
S5-10 0
L1000A
S5-10
0: Disabled
1: Direct Landing
2: Leveling Distance Control
Deceleration Distance
─
─
S5-11
0
mm
─
Stop Distance
─
─
S5-12
0
mm
─
Short Floor
Opera
tion
Direct Landing Minimum
Speed Level
─
─
S5-13
20.0 %
Sets the speed level for the start of Direct Landing.
Motor Contactor Response
Error (Detection/Reset Select)
─
─
S6-01 0
L1000A
S6-01
0: Detect during stop, SE1 manually reset
1: Detect during stop, SE1 automatically reset
2: No SE1 detection
Error De
te
ction
Starting Current Error (SE2)
Detection Delay Time
─
─
S6-02
200
ms
─