beautypg.com

Yaskawa F7 to L1000A User Manual

Page 44

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 44 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Digi

tal Outp

ut

s

Terminal P2 Function
Selection

H2-05 F

Terminal A1 Signal Level

Selection

H3-01 0 H3-01 0

Terminal A1 in L1000A is multi-functional.

F7 L1000A

H3-01 H3-01
0: 0 to +10 V

0: 0 to +10 V (uses lower limit)

1: -10 to 10 V

1: 0 to ±10 V (no lower limit)

Terminal A1 Function

Selection

H3-02 0

Terminal A1 Gain Setting

H3-02

100.0%

H3-03

100.0%

F7 L1000A

Setting Range
0.0 % to 1000.0 %

-999.9 % to 999.9%

Analog Inpu

ts

Terminal A1 Bias Setting

H3-03

0.0%

H3-04

0.0%

F7 L1000A

Setting Range
-100.0 % to 100.0 %

-999.9 % to 999.9%

Terminal A3 Signal Level
Selection

H3-04 0 ─

No corresponding parameter in L1000A.