beautypg.com

Yaskawa F7 to L1000A User Manual

Page 37

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 37 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

PG-E3 R Track Selection

F1-63 0

L1000A

F1-63
0: Disabled
1: Enabled

Analog Command

Card

Bi-polar or Uni-polar Input
Selection

F2-01 0 ─

No corresponding parameter in L1000A.

Digital Input Option Card Input
Selection

F3-01 0 F3-01 0

*The digital option card determines the setting.
DI-08: 0 (8 bit)
DI-16H: Set switch S1 to determine input signal:
S1 switch 1

: 2 (16 bit)

S1 switch S1: 1 (12 bit)

F7 L1000A

F3-01 F3-01 F3-03
0: BCD 1% units

0: BCD 1% units

0: 8 bit

1: BCD 0.1% units 1: BCD 0.1% units

1: 12 bit

2: BCD 0.01% units 2: BCD 0.01% units 2: 16 bit
3: BCD 1 Hz units

3: BCD 1 Hz units

4: BCD 0.1 Hz units 4: BCD 0.1 Hz units
5: BCD 0.01 Hz
units

5: BCD 0.01 Hz units

6: BCD, custom

6: BCD, custom

7: Binary input

7: Binary input

Digi

tal Command

Card

Bit Selection for Digital Option
Card Input Data

F3-03 2

*

Analog Moni

tor

Car

d

Channel 1 Monitor Selection

F4-01

2

F4-01

102

F7 L1000A

F4-01, F4-03, H4-01, H4-04,
o1-01

F4-01, F4-03, H4-01, H4-04,
o1-01

01: Frequency reference

101: Frequency reference

02: Output frequency

102: Output frequency

03: Output current

103: Output current

05: Motor speed

105: Motor speed

06: Output voltage
reference

106: Output voltage
reference

07: Main circuit DC voltage 107: Main circuit DC voltage
08: Output power

108: Output power

09: Torque ref (Internal)

109: Torque ref (Internal)

15: Freq ref, A1 voltage

113: Freq ref, A1 voltage

16: Freq ref, A2 voltage

114: Freq ref, A2 voltage

17: Freq ref, A3 voltage

115: Freq ref, A3 voltage

18: Secondary current (Iq)

601: Secondary current (Iq)

19: Motor excitation current
(Id)

602: Motor excitation
current (Id)

20: Output after soft start

116: Output after soft start

21: ASR input

603: ASR input

22: ASR output

604: ASR output

24: PID feedback amount

501: PID feedback amount

26: Output voltage ref (Vq) 605: Output voltage ref (Vq)

27: Output voltage ref (Vd)

606: Output voltage ref
(Vd))

32: ACR output (q-axis)

607: ACR output (q-axis)

33: ACR output (d-axis)

608: ACR output (d-axis)

36: PID input amount

502: PID input amount

37: PID output amount

503: PID output amount

38: PID setpoint

504: PID setpoint

44: ASR output , no filter

625: ASR output , no filter

45: Feed Forward output

626: Feed Forward output