Yaskawa F7 to L1000A User Manual
Page 37
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 37 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
PG-E3 R Track Selection
─
─
F1-63 0
L1000A
F1-63
0: Disabled
1: Enabled
Analog Command
Card
Bi-polar or Uni-polar Input
Selection
F2-01 0 ─
─
No corresponding parameter in L1000A.
Digital Input Option Card Input
Selection
F3-01 0 F3-01 0
*The digital option card determines the setting.
DI-08: 0 (8 bit)
DI-16H: Set switch S1 to determine input signal:
S1 switch 1
: 2 (16 bit)
S1 switch S1: 1 (12 bit)
F7 L1000A
F3-01 F3-01 F3-03
0: BCD 1% units
0: BCD 1% units
0: 8 bit
1: BCD 0.1% units 1: BCD 0.1% units
1: 12 bit
2: BCD 0.01% units 2: BCD 0.01% units 2: 16 bit
3: BCD 1 Hz units
3: BCD 1 Hz units
4: BCD 0.1 Hz units 4: BCD 0.1 Hz units
5: BCD 0.01 Hz
units
5: BCD 0.01 Hz units
6: BCD, custom
6: BCD, custom
7: Binary input
7: Binary input
Digi
tal Command
Card
Bit Selection for Digital Option
Card Input Data
─
─
F3-03 2
*
─
Analog Moni
tor
Car
d
Channel 1 Monitor Selection
F4-01
2
F4-01
102
F7 L1000A
F4-01, F4-03, H4-01, H4-04,
o1-01
F4-01, F4-03, H4-01, H4-04,
o1-01
01: Frequency reference
101: Frequency reference
02: Output frequency
102: Output frequency
03: Output current
103: Output current
05: Motor speed
105: Motor speed
06: Output voltage
reference
106: Output voltage
reference
07: Main circuit DC voltage 107: Main circuit DC voltage
08: Output power
108: Output power
09: Torque ref (Internal)
109: Torque ref (Internal)
15: Freq ref, A1 voltage
113: Freq ref, A1 voltage
16: Freq ref, A2 voltage
114: Freq ref, A2 voltage
17: Freq ref, A3 voltage
115: Freq ref, A3 voltage
18: Secondary current (Iq)
601: Secondary current (Iq)
19: Motor excitation current
(Id)
602: Motor excitation
current (Id)
20: Output after soft start
116: Output after soft start
21: ASR input
603: ASR input
22: ASR output
604: ASR output
24: PID feedback amount
501: PID feedback amount
26: Output voltage ref (Vq) 605: Output voltage ref (Vq)
27: Output voltage ref (Vd)
606: Output voltage ref
(Vd))
32: ACR output (q-axis)
607: ACR output (q-axis)
33: ACR output (d-axis)
608: ACR output (d-axis)
36: PID input amount
502: PID input amount
37: PID output amount
503: PID output amount
38: PID setpoint
504: PID setpoint
44: ASR output , no filter
625: ASR output , no filter
45: Feed Forward output
626: Feed Forward output