beautypg.com

Yaskawa F7 to L1000A User Manual

Page 48

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 48 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Motor Temperature Input
Filter Time

L1-05 0.20

s

Momentary Power Loss
Operation Selection

L2-01 0 ─

Momentary Power Loss Ride-
Thru Time

L2-02 * ─

Momentary Power Loss
Minimum Baseblock Time

L2-03 * ─

Momentary Power Loss
Voltage Recovery Ramp Time

L2-04 * ─

No corresponding parameter in L1000A.

Undervoltage Detection Level

L2-05

190 V

L2-05

190 V

380 V for a 400 class drive.
But if E1-01 is set lower than 400, then for set 350 V for
L1000A.

KEB Deceleration Time

L2-06*

0.0 s

Acceleration Time After Power
Recovery

L2-07 0.0

s

Momentar

y Po

wer

Loss

KEB Ride-Thru Start Output
Frequency Reduction

L2-08 100%

No corresponding parameter in L1000A.

Stall Prevention Selection
during Acceleration

L3-01 1 L3-01 1

F7 L1000A

L3-01 L3-01
0: Disabled

0: Disabled

1: Enabled

1: Enabled

2: Optimum Tuning

2: Optimum Tuning

Stall Prevention Level during
Acceleration

L3-02 150% L3-02 150%

*

*Upper limit is determined by L8-38.

Stall Prevention Limit during
Acceleration

L3-03 50% L3-03

Stall Prevention Selection
during Deceleration

L3-04 1 ─

No corresponding parameter in L1000A.

Stall Prevention Selection
during Run

L3-05 1 L3-05 1

F7 L1000A

L3-05 L3-05
0: Disabled

0: Disabled

1: Enabled (Decel Time 1)

1: Enabled (Decel Time 1)

2: Enabled (Decel Time 2)

2: Enabled (Decel Time 2)

Stall Prevention Level during
Run

L3-06 150% L3-06 150%

Overvoltage Inhibit Selection

L3-11

0

Stall

Pre

ven

tion Fu

ncti

on

F7 : Overvoltage Suppression
Voltage Level
L1000A: Overvoltage
Suppression and Stall
Prevention Desired DC Bus
Voltage

L3-12 380

V*

No corresponding parameter in L1000A.

Speed Agreement Detection
Level

L4-01 0.0

Hz L4-01 0.0

%

Speed Agreement Detection
Width

L4-02 2.0

Hz L4-02 4.0

%

Speed Agreement Detection
Level (+/-)

L4-03 0.0

Hz L4-03 0.0

%

Frequency De

te

ctio

n

Speed Agreement Detection
Width (+/-)

L4-04 2.0

Hz L4-04 4.0

%