Product Transition Guide – F7 to L1000A

F7

L1000A

Parameter Name

Parameter

Default

Setting

Record

Parameter

Default

Comments:

Gray shading indicates default setting.

Motor 2 Mid. Output
Frequency Voltage

E3-06 15.0

V

*

E3-08 11.0

V

*

*Determined by the control mode selected.
Double values for 400 V class drives.

Motor 2 Minimum Output
Frequency

E3-07 1.5

Hz

*

E3-09 0.5

Hz

*

*Determined by the control mode selected.

Motor 2 Minimum Output
Frequency Voltage

E3-08 9.0

V

*

E3-10 2.0

V

*

*Determined by the control mode selected.
Double values for 400 V class drives.

Motor 2 Rated Current

E4-01

*

E4-01

*

*Determined by drive capacity.

Motor 2 Rated Slip

E4-02

*

E4-02

*

*Determined by drive capacity.

Motor 2 De-Coupled Load
Current

E4-03

*

E4-03

*

*Determined by drive capacity.

Motor 2 Motor Poles

E4-04

4Poles

E4-04

4Poles

Motor 2 Line-to-Line
Resistance

E4-05

*

E4-05

*

*Determined by drive capacity.

Motor 2 Leakage Inductance

E4-06

*

E4-06

*

*Determined by drive capacity.

Motor 2

Pa

rameter

Motor 2 rated capacity

E4-07

*

E4-11

*Determined by drive capacity.

Motor rated power

E5-02 *

PM Motor Settings
*Determined by drive capacity.

PM

M

otor

Se

ttings

Motor rated current

E5-03 *

PM Motor Settings
*Determined by drive capacity.

Motor Poles

E5-04 12

Motor Stator Resistance
(Single Phase)

E5-05 *

PM Motor Settings
*Determined by drive capacity.

Motor d-Axis Inductance

E5-06 *

PM Motor Settings
*Determined by drive capacity/Set during Auto-Tuning

Motor q-Axis Inductance

E5-07 *

PM Motor Settings
*Determined by drive capacity/Set during Auto-Tuning

Motor Induction Voltage
Constant 1

E5-09 *

PM Motor Settings
*Determined by drive capacity and motor nameplate data.

Encoder Offset

E5-11

0.0

deg

Set during parameter or encoder offset auto-tuning for PM
motors.

Motor Inductance Voltage
Constant 2

E5-24

0.0

mv/(r/min)

PG Constant

F1-01

1024

F1-01

1024

*Determined by drive capacity.
CLV/PM mode, maximum setting is 15000 ppr.