Yaskawa F7 to L1000A User Manual
Page 35
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 35 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Motor 2 Mid. Output
Frequency Voltage
E3-06 15.0
V
*
E3-08 11.0
V
*
*Determined by the control mode selected.
Double values for 400 V class drives.
Motor 2 Minimum Output
Frequency
E3-07 1.5
Hz
*
E3-09 0.5
Hz
*
*Determined by the control mode selected.
Motor 2 Minimum Output
Frequency Voltage
E3-08 9.0
V
*
E3-10 2.0
V
*
*Determined by the control mode selected.
Double values for 400 V class drives.
Motor 2 Rated Current
E4-01
*
E4-01
*
*Determined by drive capacity.
Motor 2 Rated Slip
E4-02
*
E4-02
*
*Determined by drive capacity.
Motor 2 De-Coupled Load
Current
E4-03
*
E4-03
*
*Determined by drive capacity.
Motor 2 Motor Poles
E4-04
4Poles
E4-04
4Poles
Motor 2 Line-to-Line
Resistance
E4-05
*
E4-05
*
*Determined by drive capacity.
Motor 2 Leakage Inductance
E4-06
*
E4-06
*
*Determined by drive capacity.
Motor 2
Pa
rameter
Motor 2 rated capacity
E4-07
*
E4-11
─
*Determined by drive capacity.
Motor rated power
─
─
E5-02 *
PM Motor Settings
*Determined by drive capacity.
PM
M
otor
Se
ttings
Motor rated current
─
─
E5-03 *
PM Motor Settings
*Determined by drive capacity.
Motor Poles
─
─
E5-04 12
Motor Stator Resistance
(Single Phase)
─
─
E5-05 *
PM Motor Settings
*Determined by drive capacity.
Motor d-Axis Inductance
─
─
E5-06 *
PM Motor Settings
*Determined by drive capacity/Set during Auto-Tuning
Motor q-Axis Inductance
─
─
E5-07 *
PM Motor Settings
*Determined by drive capacity/Set during Auto-Tuning
Motor Induction Voltage
Constant 1
─
─
E5-09 *
PM Motor Settings
*Determined by drive capacity and motor nameplate data.
Encoder Offset
─
─
E5-11
0.0
deg
Set during parameter or encoder offset auto-tuning for PM
motors.
Motor Inductance Voltage
Constant 2
─
─
E5-24
0.0
mv/(r/min)
─
PG Constant
F1-01
1024
F1-01
1024
*Determined by drive capacity.
CLV/PM mode, maximum setting is 15000 ppr.