beautypg.com

2 windy boy 5000tl, Windy boy 5000tl – SMA WB 3600TL User Manual

Page 88

background image

Technical Data

SMA Solar Technology AG

88

WB36TL_50TL-IEN102011

Installation Guide

14.2 Windy Boy 5000TL

DC Input

* The maximum open circuit voltage, which can occur at a cell temperature of −10 °C, may not exceed the maximum input voltage.

AC Output

* Depends on country configuration

Maximum DC voltage*

550 V

MPP input voltage range

80 V … 440 V

Minimum open circuit voltage to activate "Turbine Mode"

125 V

DC nominal voltage

400 V

Maximum input current

2 x 15 A

Maximum DC power

5,300 W

Voltage ripple

< 10 % of the input voltage

AC nominal output*

4,600 W  / 5,000 W

Maximum AC power

5,000 W

Nominal AC current

20 A

Maximum output current

22 A

Maximum fuse protection

32 A

Harmonic distortion of output current at
AC T

HD

voltage < 2 %,

AC power > 0.5 AC nominal power

< 3 %

Nominal AC voltage

220 V / 230 V / 240 V

AC voltage range, extended operating range*

180 V … 280 V

AC grid frequency*

50 Hz / 60 Hz

Tolerance at AC grid frequency

± 5 Hz

Power factor at nominal AC power

1

Overvoltage category

III

Test voltage at 50 Hz
(1 s routine testing / 5 s type testing)

1.4 kV

Surge testing voltage

4 kV

Serial interface

6 kV

Internal consumption in standby

< 0.5 W