beautypg.com

SMA WB 3600TL User Manual

Page 60

background image

Disconnecting the Inverter

SMA Solar Technology AG

60

WB36TL_50TL-IEN102011

Installation Guide

6. Loosen all six captive screws and remove the

bottom housing lid.

7. Ensure there is no current at any DC cables using a

clip-on ammeter.
☑ If there is a current present, check the

installation.

8. Unlock the connected DC plug connectors using a

screwdriver:
– Insert a screwdriver into one of the slits on the

sides (1).

– Lever the screwdriver upward (2) and pull out

the plug connector (3).

This manual is related to the following products: