SMA Solar Technology AG

Initial start-up

Installation Guide

WB36TL_50TL-IEN102011

57

6.1.4 Restarting the Self-Test

In order to restart the self-test, proceed as follows:

1. Disconnect the line circuit breaker and secure against re-connection.
2. Disconnect the multi-function relay power supply, if available.
3. Disconnect the Electronic Solar Switch from the inverter for 5 minutes and then connect it again.

☑ The inverter is now in the initialization phase and you can restart the self-test, as described in

section 6.1.1 ”Starting the Self-Test by Tapping” (page 52) from point 3.

6.2 Display Messages during Initialization

• Firstly, the firmware version of the internal

processors appears in the text lines.

• After 5 seconds or after tapping the enclosure lid,

the serial number or the description of the inverter
appears. This description can be changed with a
communications device.

• After a further 5 seconds, or when you tap again,

the configured standard is displayed.

• After a further 5 seconds, or when you tap again,

the configured language is displayed.

• In normal operation the scrolling line of the display is subsequently empty. You can refer to the

possible event messages in the scrolling lines and their meaning in section 11 ”Messages”
(page 70).