Electrical Connection

SMA Solar Technology AG

42

WB36TL_50TL-IEN102011

Installation Guide

Should the inverter not be set to the installation country, configure it using the 2 rotary switches as
described in section 5.5.2 ”Setting the Country Standard and Language using Rotary Switches”
(page 43).
Alternatively you can adjust the settings via the parameter "CntrySet" and / or "Set country standard"
using a communication device.
If you require adjusted parameter settings for you installation location, you can change these using a
communication device.

6

6

EN 50438

Not programmed**

Yes

various EU
countries

7

0

EN50438-CZ

Not programmed**

Yes

Czech Republic

7

1

EN50438-CZ

English

Yes

Czech Republic

7

2

EN50438-CZ

German

Yes

Czech Republic

7

8

C10/11*

French

Yes

Belgium

7

9

C10/11*

English

Yes

Belgium

7

A C10/11*

German

Yes

Belgium

E

0

Off-grid 60 Hz

English

no

Flexibility

E

1

Off-grid 60 Hz

German

no

Flexibility

E

2

Off-grid 60 Hz

French

no

Flexibility

E

3

Off-grid 60 Hz

Spanish

no

Flexibility

E

4

Off-grid 60 Hz

Italian

no

Flexibility

E

5

Off-grid 60 Hz

Not programmed**

no

Flexibility

E

6

Off-grid 60 Hz

Not programmed**

no

Flexibility

a)

Special setting: parameter "VolCtl.Rpro" or "Voltage increase protection" = 244 V instead of 253 V

b)

Special setting: Bluetooth transmission power reduced (in accordance with French standards)

*)

Availability on request

**) Currently unavailable. The previously configured display language remains set.

(A) (B) Country data set

Display language

Grid guard
protection

Country