5.4.2 Assembling the DC Plug Connector

Connection cables of the Windy Boy Protection Box (WBP-Box 500-11) must be equipped the
included with DC plug connectors to connect them to the inverter.
To assemble the DC plug connectors, proceed as detailed below. Ensure the plug connectors have
the correct polarity. The DC plug connectors have the symbols "+" and " − ".

Cable requirements:

• Use a PV1-F cable.

Procedure

1. Insert stripped cable into the plug up to the limit.

2. Press the clamping clip down until it audibly snaps

into place.

3. Ensure the cable is correctly in place:

Result

Action

☑ If the conductors are visible in the hollow

cavity of the clamping clip, the cable is in
the correct position.

• Proceed to step 4.