5.6.1 Multi-function relay
The inverter is equipped with a multi-function relay as standard. This can be activated, for instance,
simultaneously with the red error LED beside the display. Other functions are being planned can be
later retrofitted via a firmware update.
Here you can connect separate loads both in the event of errors and for trouble-free operation.
The following table gives you the maximum permissible voltages and currents:
Cable requirements
The cable type and cable-laying method must be appropriate to the application and location.
Line circuit breaker
If you are connecting the multi-function relay to the public grid, it must be protected with a separate
line circuit breaker.
Voltage
Current
AC
max. 240 V
max. 1.0 A
DC
max. 30 V
max. 1.0 A
Position
Description
Value
A
Cable type
Double insulated
B
External diameter
5 mm … 12 mm
C
Cross section of insulated conductor 0.08 mm² … 2.5 mm²
D
Strip insulation
max. 8 mm
E
Stripping length
max. 15 mm