4. Execute the copy command with the following syntax:

copy tftp flash [ < primary | secondary

> ]

Note that if you do not specify the flash destination, the TFTP download defaults to the primary
flash.

For example, to download a software file named T_13_23.swi from a TFTP server with the IP
address of 10.16.34.3 1, use the following:

ProCurve # copy tftp flash 10.16.34.3 T_13_23.swi

5. When prompted

The primary OS image will be deleted. continue [y/n]?

, press

Y

.

When the switch finishes downloading the software file from the server, it displays the progress
message

Validating and Writing System Software to FLASH...

6. Wait until the CLI prompt re-appears, then continue with the next step in this procedure.

7. Check the version of firmware on the switch. To do this, type the following, then press

Enter

:

show flash

Information is displayed similar to the following example:

HP_iSCSI_switch1# show flash
Image Size(Bytes) Date Version
----- ---------- -------- -------
Primary Image : 6737518 07/25/08 T.13.23
Secondary Image : 5886358 10/26/06 T.11.12
Boot Rom Version: K.12.12
Current Boot : Primary

8. Verify that the new software version is in the expected flash area (primary or secondary).

9. Restart the switch from the flash area that holds the new software (primary or secondary).

Setting up the control point PC

To set up the Control Point PC, you have the following options:

Use the Grass Valley Control Point PC that comes from the factory with software pre-installed.

Use a PC that you own and install the required software.

1. For either option, you must do the following for the Control Point PC that runs the K2 System

Configuration application:

a) Assign a control network IP address to the PC.
b) Connect the PC to the GigE control network.

2. To use your own PC, you must additionally do the following:

a) Verify that the PC meets system requirements.
b) Install the K2 Control Point software.
c) Install SiteConfig software.
d) Install other supporting software.
e) Install and license NetCentral server software. This can be on the K2 SAN control point PC

or on a separate NetCentral server PC that monitors the K2 SAN.