Grass Valley K2 (Summit 3G) 10Gv2 Storage Area Network Installation v.8.1 User Manual
Page 144

Configure iSCSI Bridge Server Configuration page - Basic K2 SAN
This page manages the components that bridge between iSCSI (the GigE media network) and the
Fibre Channel connection to the RAID storage. You configure network settings on the iSCSI adapters
and the page validates that the Fibre Channel adapter is in place and that the media RANKs are
visible as iSCSI targets.
1. Select an iSCSI adapter and do the following:
a) Click
Modify
.
A network configuration dialog box opens.
b) Verify or enter the media network IP address and the subnet mask.
c) Click
Apply
.
d) Click
View Target Drives
.
e) Verify that all drives are shown in the
Drives exposed as iSCSI targets
field.
2. Repeat the previous step for the other iSCSI adapters.
144
K2 SAN Installation and Service Manual
02 February 2012
Configuring and licensing the K2 SAN