Redundant server heartbeat serial cable

Take care to use the proper serial cable to interconnect redundant K2 Media Servers that take the
role of file system/database servers. This cable supports the heartbeat mechanism whereby the
servers monitor each other’s health. It is a 9 pin serial cable, but it is not a standard RS-232 null
modem cable. The heartbeat cable is supplied with your system (Grass Valley part number
174-8137-00) and has a pin configuration as follows:

1 – 4

2 – 3

3 – 2

4 – 1&6

5 – 5

6 – 4

7 – 8

8 – 7

9 – No Connect

Cable NH10GE K2 Media Server

As directed by the system diagram for your K2 SAN, cable the NH10GE K2 Media Server or Servers
for your K2 SAN using the instructions in this section

K2-SVR-NH10GE online/production

These cabling instructions apply to the following:

Dell R610 PowerEdge Server NH10GE on an online or production K2 SAN.