Configure iSCSI Bridge Server Configuration page - Redundant K2 SAN server B
This page manages the components that bridge between iSCSI (the GigE media network) and the
Fibre Channel connection to the RAID storage. You configure network settings on the iSCSI adapters
and the page validates that the Fibre Channel adapter is in place and that the media RANKs are
visible as iSCSI targets.
NOTE: The iSCSI adapters on this server must be on a different subnet than those on its
redundant server partner.
1. Select
Backup
.
2. Select an iSCSI adapter and do the following:
a) Click
Modify
.
A network configuration dialog box opens.
b) Verify or enter the media network IP address and the subnet mask.
c) Click
Apply
.
d) Click
View Target Drives
.
e) Verify that all drives are shown in the
Drives exposed as iSCSI targets
field.