beautypg.com

Installing the fibre channel card driver – Grass Valley K2 (Summit 3G) 10Gv2 Storage Area Network Installation v.8.1 User Manual

Page 296

background image

11. After making settings on the iSCSI interface adapter or adapters, on the iSCSI bridge page, click

Check

.

A “…Replaced iSCSI port…” message and a “…Added iSCSI port…” message appears for each
port on the adapter or adapters that you replaced.

12. If you are replacing iSCSI interface adapters on multiple K2 Media Servers, repeat this procedure

on the remaining K2 Media Servers.

13. Place the devices of the K2 SAN back online.

Installing the Fibre Channel card driver

When you restore a K2 Media Server from the generic disk image, the 8Gb Fibre Channel card
driver is not on the disk image. After restoring the disk image, you must install the Fibre Channel
card driver as instructed in this procedure.

1. After restoring the disk image and restarting the K2 Media Server, a Found New Hardware

wizard opens. Dismiss the wizard and continue with this procedure.

2. Navigate to the following directory:

C:\Profile\Drivers\Atto 8Gb HBA Drivers

3. Open the directory for the K2 Media Server platform on which you are installing, as follows:

Platform type

Directory

64 bit

x64

32 bit

x86

4. Open

setup.exe

.

An install wizard opens.

5. Restart the K2 Media Server

Recovering from a failed K2 Media Server system battery

The following procedure applies to K2 Media Servers based on the Dell 2850/2950 platform. K2
Media Servers on other Dell models can have similar procedures. Refer to the service documentation
on the Dell Documentation CD for specific procedures.

When the system battery in a K2 Media Server fails (non rechargeable) the system configuration is
lost, and the system will not complete startup processes when the battery is replaced.

1. Restart the K2 Media Server.

A startup screen displays the message “Invalid configuration information - Please run setup
program. Time of day not set - Please run setup program.”

2. Press

F2

to enter setup.

3. Set the system date and time

4. Select

System Setup | Integrated Devices

5. Select

RAID

. This also sets ChA and ChB to RAID

296

K2 SAN Installation and Service Manual

02 February 2012

Administering and maintaining the K2 SAN