beautypg.com

Grounding requirements for personnel – Grass Valley K2 System Guide v.9.0 User Manual

Page 22

background image

Grounding Requirements for Personnel

The information in this section is provided to assist you in selecting a grounding method. This
information is taken from ANSI/ESD S20.20-2007 (Revision of ANSI/ESD S20.20-1999).

Product Qualification

Required Limits

Test Method

Personnel Grounding Technical
Requirement

< 3.5 x 10

7

ohm

ANSI/ESD S1.1 (Section 5.11)

Wrist Strap System*

< 3.5 x 10

7

ohm

ANSI/ESD STM97.1

Flooring / Footwear System –
Method 1

< 10

9

ohm

ANSI/ESD STM97.
1ANSI/ESD STM97.2

Flooring / Footwear System –
Method 2 (both required)

< 100 V

ANSI/ESD STM97.2

Product qualification is normally conducted during the initial selection of ESD control products and
materials. Any of the following methods can be used: product specification review, independent
laboratory evaluation, or internal laboratory evaluation.

Compliance Verification

Required Limits

Test Method

Personnel Grounding Technical
Requirement

< 3.5 x 10

7

ohm

ESD TR53 Wrist Strap Section

Wrist Strap System*

< 3.5 x 10

7

ohm

ESD TR53 Flooring Section and
ESD TR53 Footwear Section

Flooring / Footwear System –
Method 1

< 1.0 x 10

9

ohm

ESD TR53 Flooring Section and
ESD TR53 Footwear Section

Flooring / Footwear System –
Method 2 (both required)

* For situations where an ESD garment is used as part of the wrist strap grounding path, the total
system resistance, including the person, garment, and grounding cord, must be less than 3.5 x 10

7

ohm.

22

K2 System Guide

06 November 2012

Safety Summaries