1. Connect the K2 client and RAID devices as shown in the following illustrations.
!
OK
~AC
C1
C2
C3
C4
USB/1394
100BT/1000BT
GPI
VGA
REF. LOOP THROUGH
!
OK
~AC
K2 Summit system
To K2 RAID
Controller
To K2 RAID
Controller
Connect K2 client Fibre Channel ports to RAID controllers. Connect Fibre Channel port 1 to
RAID controller 0. If you have the redundant controller, connect Fibre Channel port 2 to RAID
controller 1.
Connect RAID controller LAN ports to control ports on a K2 GigE switch. If you have redundant
switches, connect controller 0 to switch A and controller 1 to switch B.
Connect RAID controller DP0 ports to the first Expansion chassis DP-IN ports.
Connect remaining Expansion chassis using DP-OUT and DP-IN ports.