beautypg.com

Powering on k2 g10v2 raid – Grass Valley K2 System Guide v.9.0 User Manual

Page 195

background image

6. Press

Enter

.

The software is installed. The command prompt window reports progress.

7. Restart the computer on which you installed MPIO.

8. After restart, to verify that the software is installed, on the Windows desktop right-click

My

Computer

and select

Manage

.

The Computer Management window opens.

9. In the left pane select

Device Manager

.

10. In the right pane open the

System devices

node and verify that

GVG ISCSI Multi-Path Device

Specific Module

is listed.

Powering on K2 G10v2 RAID

This topic applies to K2 G10v2 (M100) RAID.

1. Verify power and cabling.

2. Tap the power button on the controller, as shown.

NOTE: Do not press and hold down the power button.

If the RAID chassis has two controllers, you can tap the power button on either controller. You
do not need to tap both power buttons.

Tapping the power button on a controller also powers on any connected Expansion chassis. There
are no power buttons on Expansion chassis.

06 November 2012

K2 System Guide

195

Direct Connect Storage

This manual is related to the following products: