6. Press
Enter
.
The software is installed. The command prompt window reports progress.
7. Restart the computer on which you installed MPIO.
8. After restart, to verify that the software is installed, on the Windows desktop right-click
My
Computer
and select
Manage
.
The Computer Management window opens.
9. In the left pane select
Device Manager
.
10. In the right pane open the
System devices
node and verify that
GVG ISCSI Multi-Path Device
Specific Module
is listed.
Powering on K2 G10v2 RAID
This topic applies to K2 G10v2 (M100) RAID.
1. Verify power and cabling.
2. Tap the power button on the controller, as shown.
NOTE: Do not press and hold down the power button.
If the RAID chassis has two controllers, you can tap the power button on either controller. You
do not need to tap both power buttons.
Tapping the power button on a controller also powers on any connected Expansion chassis. There
are no power buttons on Expansion chassis.