6 exiting setup configuration mode – Amer Networks SS2R48G4i V2 User Manual
Page 29
SS2R24G4i/SS2R48G4i
18
Please input the read-write access community string[private]
Note the valid length for a read-write access community string is 1 to 255 characters, the default value
is “private”. When a valid read-write access community string is entered, pressing Enter returns you to
the SNMP configuration menu.
Select “1” in the SNMP configuration menu and press Enter, the following screen will appear
Please input the read-only access community string[public]
Note the valid length for a read-only access community string is 1 to 255 characters, the default
value is “public”. When a valid read-only access community string is entered, press Enter returns to the
SNMP configuration menu.
Select “2” in the SNMP configuration menu and press Enter, the following screen will appear
Please input traps-host IP address(A.B.C.D)
When the user enters a valid IP address for Traps host and presses Enter, the following appears
Please input traps community string[public]
Note the valid length for a traps community string is 1 to 255 characters, the default value is
“public”. When a valid traps community string is entered, press Enter returns to the SNMP configuration
menu.
Select “3” in the SNMP configuration menu and press Enter, the following screen will appear
Enable SNMP-server? (y/n) [y]
Type “y” and press Enter, or just press Enter to enable SNMP service, type “n” and press Enter to
disable SNMP service. The SNMP configuration menu appears.
Select “4” in the SNMP configuration menu and press Enter, the following screen will appear
Enable SNMP-traps ? (y/n) [y]
Type “y” and press Enter, or just press Enter to enable SNMP Traps, type “n” and press Enter to
disable SNMP traps. The SNMP configuration menu appears.
Select “5” in the SNMP configuration menu and press Enter, the following screen appears
Please input the new NMS IP address(A.B.C.D)
When a valid secure IP address(es) for SNMP management workstation is entered, press Enter to
return to the SNMP configuration menu.
Selecting “6” in the SNMP configuration menu will return to the Setup main menu.
3.3.6 Exiting Setup Configuration Mode
Select “5” in the Setup main menu to exit the Setup configuration mode without saving the
configurations made.