ATA-171/172/171P/171M/171+/172+

User’s Guide

will be regarded as On-Hook. From (3~12), Unit:10MS.

Maximum length is 3 bytes.

Reset [Button]

Clear the change.


Figure 3: Phone+FXO equipment

(Figure 3)

Flash Time

Default 60. Flash signal that is <(less than) 600ms, will be
regarded as transfer; flash signal that is > (more than) 600ms
will be regarded as On-Hook. From (4~255),Unit: 10MS.
Maximum length is 3 bytes.

Submit [Button]

Submit the change.

Reset [Button]

Clear the change.

5.9.3 Operate Instruction

Step 1: On the main page, select [Phone Setting

Flash Time Setting], enter [Flash Time

Setting] page, after revising information (e.g. Flash Time: 70, Max Flash Time: 100) (See
Figure 1), then click [Submit].

(Figure 1)

Step 2: After saving change, enter [Note Information] page, “Note Information” will be seen,

then the changing will come into effect.

Step 3: On the main page, select [Save Change] item, enter [Save Changes] page, and execute

the saving command by press [Save]. [Note Information] page will be seen which means
saving successfully. And the system will be restarted, please wait for a while.