beautypg.com

Editing and cloning new circuits, Editing and cloning new circuits -7, Editing and – Verilink SCM (880-503300-001) Product Manual User Manual

Page 61: Cloning new circuits

background image

Circuit Manager

Verilink SCM

5-7

When building circuits, you may need to separately activate the
circuit by selecting the command:

I) activate circuit

from the

Circuit Manager Menu.

Editing and Cloning New Circuits

This section describes how to edit an existing circuit. Time savings
are possible when creating new circuits by “cloning” an existing
circuit.

Begin to edit a circuit by typing "E" at the Circuit Manager Menu:

[127.127.127.67] [0,1] SCM > e

You are prompted to enter the name of the circuit to edit.

The Edit Circuit Menu appears with the configuration of the
specified circuit:

ST

Source Mapping: timeslots to use at

the Source Port. For T3 ports these

are level 1 (DS1) timeslots — at T1

rate each.

Note: applies to M1-3 only.

Enter the timeslots with

comma separators or a

range with a hyphen

between first and last.

For example: 1,2,3,4 or

1-4.

1-28 for T3 ports.

DM

Destination Mapping: timeslots to use

at the Destination Port. For T1 ports

these are level zero (DS0) timeslots at

56K or 64K each.

Note: applies to QUAD T1 only.

Enter the timeslots with

comma separators or a

range with a hyphen

between first and last.

For example: 1,2,3,4 or

1-4.

1-24 for T1 ports.

DT

Destination Mapping: timeslots to use

at the Destination Port. For T3 ports

these are level 1 (DS1) timeslots — at

T1 rate each.

Note: applies to M1-3 only.

Enter the timeslots with

comma separators or a

range with a hyphen

between first and last.

For example: 1,2,3,4 or

1-4.

1-28 for T3 ports.

S

Setup: used to start a fully-configured

circuit. All parameters above should

be entered first before setup is

invoked.

When Setup command is

issued Circuit Manager

will attempt to route and

initialize the circuit.

After a brief pause the

menu is redisplayed with

the status of the circuit

shown.

Should a circuit fail to

become active, check the

configuration of the

application module(s) and

verify ports used are

configured as active ports.

X

Exit: return to Circuit Manager Menu.

If the Add Circuit Menu is

exited before completing

a circuit, the incomplete

circuit is lost.

Key

Description

Range

Note