Administration Menu
Verilink SCM
4-13
I)Ethernet IP address
Enter the Ethernet IP address of the primary SCM in the node, in the
form: [0.0.0.0]. for example: [192.94.45.242]
Using Telnet with the IP address, you can initiate a Craft interface
session over Ethernet.
NOTE: If, after configuring IP addresses, an error message appears
including the text “sendto: new socket sendto fail:”, there is
an error in the IP addresses used. The Ethernet IP address
and the SLIP IP address must reflect different network
segments as per the subnet mask in use. Correct the error
and reset the SCM module to stop the error messages.
M) Ethernet subnet mask
The Ethernet subnet mask is based on the IP address according to
the standard rules for IP address classes (A,B,C etc.).
L) SLIP IP address
Serial Line Interface Protocol (SLIP) is used to establish a Telnet
Craft interface session, often through a modem. SLIP and Ethernet
addresses must reflect different networks, determined by their
subnet masks.
NOTE: Do not enter a SLIP address unless SLIP will actually be used.
When a SLIP address is entered the selected (front or rear) PRI
connector on the SCM module becomes a SLIP port instead of
a port which supports Verilink Node Manager software. If the
SLIP address is left at 0.0.0.0 the PRI port uses ACP and may
be used with Node Manager.
S) SLIP subnet mask
The SLIP subnet mask is based on the SLIP address according to
standard rules.
G) gateway IP address
The IP address of your network gateway device. This might be a
router which the SCM will use to reach an SNMP manager. A
gateway address is only required if the SCM module will be
communicating with other devices not on the same LAN segment.
Consult with your network administrator.