Administration menu commands, Administration menu, Commands – Verilink SCM (880-503300-001) Product Manual User Manual
Page 41: Table 4-1

Administration Menu
Verilink SCM
4-3
Table 4-1
Administration Menu Commands
Menu Option
Description
Instructions
H) set shelf type
Define or change shelf types of each
shelf in local node.
See the subsection:
.
T) set time
Sets time for all modules in the node.
Use format hh:mm:ss to set time. Set
the time zone, then date, and then
time. This order is important.
B) download firmware
Firmware download to selected
modules (other than the SCM itself).
W) write file to flash
Stores previously downloaded firmware
in flashbank on this SCM card.
C) set front/rear access Set management port access.
Front
or
back, not both at same time.
The default is front access.
A) set node address
Changes local node address. This is not
the Ethernet IP address. This is the
prompt line address [0.0.0.1]. The
value for each SCM must be unique.
Never set first octet greater than 127.
Will cause momentary reset of SCM as it
updates database records. Used by
Verilink Node Manager application.
I) change site name
Changes local node site name as it
appears on second line of Main Menu.
Enter up to 19 alpha-numeric
characters.
N) TCP/IP parameters
Ethernet/SLIP, SNMP, Trap Host, and
TCP/IP addresses and options.
See the section:
.
M) modem parameters SCM SLIP modem interface menu.
.
K) show shelf_master
Displays which module is driving the
backplane sync clock.
Reference information for Technical
Support. See AS3000: the Basics,
Chapter 2, “System Information”, for
further details.
X) exit this screen
Exits to SCM Main Menu.
Z) set time zone
Set time zone for all modules in node.
Select time zone from list presented, or
use custom for GMT offset in hours +/-.
Enable/Disable Daylight Savings option.
Set the time zone, then date, and then
time. This order is important.
D) set date
Set date for all modules in node.
Use the format: mm/dd/yy for month,
day, and year. Set the time zone, then
date, and then time. This order is
important.
Y) switch over once
Executes selected firmware image
ONCE. The switchover is not
permanent. Use to test firmware
upgrades.
See Chapter 6,
O) switch over
permanent
Sets which flash bank to boot from at
power up (setting saved on reset).
Q) query firmware
Displays status of firmware revisions in
partition banks of selected module.
Results displayed after about 60
seconds.