Administration Menu
4-16
Verilink SCM
Setting Time and
Date
It is important to set the time zone, date, and time in the following
order:
1. Set the time zone, including Daylight Savings, using the Z
option in the Administration Menu.
2. Set the date using the D option in the Administration Menu.
3. Set the time using the T option in the Administration Menu.
Once the time zone, date and time have been configured, they are
displayed at the top of the Administration Menu. The time may at
first appear to be a minute or two faster than the time entered. It
will self-correct back to the time that was orinally set, without any
further adjustments, in 10 to 15 minutes. The clock is not
temperature-controlled and drifts a few minutes each month,
depending on temperature variations, about as much as most PC
clocks. This does not impair the functionality of the module in any
way.
Exiting the
Administration
Menu
The option:
X) exit this screen
returns you to the SCM Main Menu.
K
Dial-out connect timeout. The length of time in seconds that the SCM will wait for DCD, a
value of zero disables this option and allows modem shift register 7 to handle timeout.
I
Dial-out inactive timeout. Length of time in seconds that the SCM will allow the connection
to remain established when idle (no data). A value of zero disables this option.
S
Manual dial-out. Commands the modem to dial the phone number shown now. Useful for
testing the modem configuration.
W
Set default commands. Restores all of the user options on this submenu to factory defaults.
H
Hangup. Commands the modem to hangup and return to an on-hook condition. This might
be used to end a modem test.
A
Manual answer, commands the modem to answer now. Use to verify that the SCM and
modem are communicating properly.
X
Exit. Returns to the Administration Menu.
Command
Usage