SCM Overview

1-6

Verilink SCM

Alarm Relay

The NIM rear panel provides alarm relay outputs. The Form C alarm
relay provides normally open (NO), normally closed (NC), and
common (CO) contacts. The relay is triggered by alarms that may
occur within the node, including the failure of one SCM in a node
with redundant SCMs.

Figure 1-3 NIM 3000 Rear Connector Module, Rear Panel

Craft Interface

The SCM Craft interface is a menu-driven ASCII user interface. It is
supported by all modules in the node. It can be accessed locally, or
remotely via Telnet over SLIP or Ethernet.

An SCM installed in each node unifies a network via inband
management. A local SCM can support a terminal session extended
to the remote SCM. The remote SCM in turn, can communicate with
the firmware of the application modules in its node.

Each local SCM can manage one node of one shelf containing up to
13 modules.

Figure 1-4

shows an example QUAD T1 application.

Management PRI

RS-232

RJ-45

ACP management over RS-232

Management EXT

RS-232

RJ-45

ACP management over RS-232

Ethernet

10 Mbit/s Ethernet

AAUI

TCP/IP/Telnet/SNMP/FTP via external

Ethernet transceiver (supplied)

Port Label on NIM 3000

Interface

Connector

Protocol Support

ALARM

RELAY

NO COM NC

311

-10X

X

X

X

001

INPUT

EXT TIMING

SLIP

ETHERNET

PRI

EXT

NIM

300

0

DB-25 male

Dual RJ-45

AAUI-14

female