beautypg.com

MultiDyne ACI-2058 User Manual

Page 119

background image

W

EB

X v2.50 User Manual

Chapter 7: View

A54-3000-100 A

80

A

PCON

, Inc.

Zoning

Indicates whether you can specify or use zones.
Clicking the Edit link, viewable only by users with Administrator
permission privileges, displays the

Zoning

screen where you can

change the IP address. For details about this screen, see
page 70.
Note: You can also access this screen by selecting
Configuration>Zoning.

Port Locking

Indicates whether you can reserve specified ports exclusive use.
Clicking the Edit link, viewable only by users with Administrator
permission privileges, displays the

Locks

screen where you can

change the IP address. For details about this screen, see
page 54.
Note: You can also access this screen by selecting
Configuration>Port Locking.

Power

Indicates whether power is supplied to the switch.
The ACI-2058, 288-port switch, includes three power supplies.
One is required to power on the motherboard. At least two must
function to fully power the unit, including the blades.
Other switches, such as the 144- and 64-port switches, include
two power supplies. Only one is required to power on the
motherboard and to fully power the unit.

Temperature

Indicates temperature and status:
Green: Internal temperature is within specified limits.
Flashing red: Internal temperature exceeds the specified limit.

If this occurs, the switch also emits an audible alarm, if
enabled. For details, see

Properties

on page 133.

The default temperature’s maximum threshold is 50º C. To
change the default, click the Edit link, viewable only by users with
Administrator permission privileges and located to the right of
Switch Name, to display the

Properties

screen. For details about

this screen, see page 133.
Note: You can also access this screen by selecting
Configuration>Switch Properties.

Power Supply n Alarm

Indicates operational status of the specified power supply.
Green: The power supply is functioning normally.
Flashing red/amber: The power supply failed. If this occurs, the

switch also emits an audible alarm if enabled. For details, see

Audible alarms enabled

on page 138.

SFP Warnings

Indicates operational status of SFP temperature, power, and
received signal. Checks the transmit signal only if Automatic
Transmitter Disable is set to

TX

on

when

no

RX

. For details about

this option, see

Properties

on page 133.

Green: The SFP is functioning within normal thresholds.
Flashing red: One or more SFPs have exceeded the warning

threshhold defined by the SFP manufacturer. To determine
which SFP(s) failed, click the field label to display the

Alarms

screen. For details about this screen, see page 61.

Field