beautypg.com

2 - operation reference, A note regarding wbk option cards and modules, Operation reference 2 – Measurement Computing StrainBook/616 User Manual

Page 15: Strainbook fan

background image

Operation Reference

2

A Note Regarding WBK Option Cards and Modules …… 2-1
Basic Operation …… 2-2
Triggers …… 2-7
Synchronizing Multiple StrainBooks …… 2-8
Programmable Features …… 2-10
Operational Tips …… 2-10


A Note Regarding WBK Option Cards and Modules

Reference Note: The following WBK options can be used with StrainBook systems.

o

WBK16/LC is discussed in chapter 6 of this user’s manual.

o

Refer to the WBK Option Cards and Modules User’s Manual (p/n 489-0902) for detailed information

regarding other WBK options. A PDF version of the document is included on the data acquisition CD.

WBK

Description

Hardware Type

WBK10A

8-Channel Expansion Chassis

Expansion Module

WBK11A *

8-Channel SSH Card

Signal Conditioning Card

WBK12A *

8-Channel Programmable Low-Pass Filter Card

Signal Conditioning Card

WBK13A *

8-Channel Programmable Low-Pass Filter Card with SSH**

Signal Conditioning Card

WBK15

8-Channel Isolated (5B) Signal Conditioning Module

Expansion Module

WBK16

8-Channel Strain Gage Module

Expansion Module

WBK16/SSH

8-Channel Strain Gage Module with SSH

Expansion Module

WBK16/LC

1-Channel Load Cell, Shunt Cal Internal Option (see ch. 6)

Shunt Relay, plug-in

WBK17

8-Channel Counter-Input Module with Quadrature Encoder Support

Expansion Module

WBK18

8-Channel Dynamic Signal Conditioning Module with Transducer

Electronic Data Sheet support (T.E.D.S.)

Expansion Module

WBK30

Memory Expansion Cards; 16 MB, 64 MB, or 128 MB

(WBK30/16, WBK30/64, WBK30/128)

Memory Expansion Cards

WBK40 14-Channel

Thermocouple

Input Module

Expansion Module

WBK41

Multi-Function I/O Module (14-Channel T/C, 40-Channel Digital I/O,

4 Counter Inputs, 2 Timer Outputs, Optional 4 Analog Output
Channels)

Expansion Module

*

WBK11A, WBK12A, and WBK13A cannot be used directly with StrainBook. Each requires mounting within a

WBK10A if it is to be used in a StrainBook system.

** SSH is Simultaneous Sample and Hold

StrainBook Fan

The internal components of StrainBook/616 are air-cooled. Cooling to ambient occurs as long

as the surrounding environment is cooler than the unit. When the unit becomes too warm for

ambient cooling, a temperature sensor signals the fan to run.
Fan speed varies according to the unit’s internal temperature. In cooler temperatures the fan

operates at lower speeds, thus reducing audible noise.
To allow for sufficient cooling, it is important to keep the fan and vents free of obstruction.

StrainBook/616

967794

Operation Reference 2-1