beautypg.com

How are multiple strainbooks synchronized – Measurement Computing StrainBook/616 User Manual

Page 14

background image

How are Multiple StrainBooks Synchronized?

Up to four StrainBook/616 units can be synchronized to each other via their SYNC ports. Each unit has

two identical SYNC ports. Either or both SYNC ports can be used to connect to the units via SYNC cables

CA-74-1 or CA-74-5 (1-foot or 5-foot cables, respectively). The units can be scan-synchronized and

triggered from any other SYNC-connected unit.


SYNC Cables

CA-74-1 (1 ft.) or
CA-74-5 (5 ft.)

Ethernet Cable
to PC

TR-40U Power
Adapter

Three StrainBook/616 Units, Synchronized

Not all trigger modes are supported in multiple StrainBook/616 Systems.

Synchronization Concept Block Diagram

The preceding diagram shows how a StrainBook/616 can input or output synchronization timing and

trigger events on either SYNC connector.

SYNC cables are not to exceed a total combined length of 15 feet (4.57 m).