CFN II Quick Reference

C09159 Rev. 2238

51

Completed Transaction Codes

Code Message*

Meaning

7

Refund

transaction is a refund**

8

Return

transaction is a return**

9

Payout

transaction is a payout**

10 Mem

Lost

pump control unit’s memory was lost due
to battery failure

40 Pwr

Fail

transaction terminated due to a power
failure at the pump control unit

41

normal

transaction

42

Timed Out

transaction timed out at the pump

43

Limit

pump cut off at limit

45

Reversal

transaction is a reversal

50 Unassigned

a device completed a transaction but the
Site Controller does not have a record of it

52

Gate

transaction was started at a gate controller

54 Aborted

transaction was aborted (pump was
deactivated) before pumping was
completed

55 Delivery

transaction is a fuel delivery, either
manually entered at the card reader
terminal or registered by a tank monitor

71 Manual

transaction was manually entered at the
card reader terminal***

77

Pulse err

caused by dual pulser failure

78 Prod

out

pump reports it is out of this type of
product

79

Pump down

a pump is not working**

81

Withdrawal

transaction was a cash withdrawal**

*The message printed in the Error field of the
transaction printout.
**Site Controller II only.
***Site Controller I only.

Site-Host Mode

Standard log in—an example of the sign-on
command and response with calculated CRC-16
check sums:

01CK0GASBOYE7B6

01CK0008511251408000600060006000100202V0
10,D389

PC/Site Control

Required Settings

for SC II

Network Poll Address = 1.

Site ID = site ID in PC password file.

Password for user 1 is identical in PC password file.

Baud rate correct for modem and its switches.

Command Line Options

SC [/Aargument] [/Bbaud] [/Ccom#] [/Dphone] [/L]
[/Ttimeout] [siteid]

/Aargument Specify an argument to be passed to a
file of Site Controller commands that is used as input
to PC/SiteControl. Multiple arguments can be sent
using multiple /A options. /A options must come
before any other parameters.

/Bbaud 300, 1200, 2400, or 9600; default is 1200

/Ccom# 1 or 2; default is 1

/Dphone Specify the phone number to dial to
connect to a Site Controller. Use this option only if
you connect to the Site Controller through a dial-out
modem and you want to override the number in the
password file. P requests pulse (rotary) dialing, T
requests touch dialing, and a comma requests the
modem to pause 2 seconds in the dialing sequence to
wait for a second dial tone.
Another phone number option is the modem timeout
length. That is the time the modem will wait for an
answer. The modem timeout length is the number of
seconds surrounded with square brackets [], typed
after the /D.

/L Output usually appears on the screen. This
option will make the output also print on the PC
printer.

/Ttimeout Specify how long to wait for a response
from the Site Controller. The time is specified in
eighteenths of a second (18 = 1 second); default and
shortest timeout allowed is 3 (0.167 seconds).

siteid Specify the site ID number. Use this option
only for sites you are dialing up with a modem, not
for direct-connect sites. Use an asterisk (*) as the site
ID to call all the sites in the password file.

Input and Output

Redirection

If you use site-control mode, the input and output
files will be on the PC’s disk, instead of the Site
Controller’s disk. Similarly, printed output will be
printed on the PC’s printer, instead of the Site
Controller’s printer.