Pc/site control, Site-host mode, Required settings for sc ii – Gasboy CFN Series CFN II Quick Reference User Manual
Page 55: Command line options, Input and output redirection, Completed transaction codes

CFN II Quick Reference
C09159 Rev. 2238
51
Completed Transaction Codes
Code Message*
Meaning
7
Refund
transaction is a refund**
8
Return
transaction is a return**
9
Payout
transaction is a payout**
10 Mem
Lost
pump control unit’s memory was lost due
to battery failure
40 Pwr
Fail
transaction terminated due to a power
failure at the pump control unit
41
normal
transaction
42
Timed Out
transaction timed out at the pump
43
Limit
pump cut off at limit
45
Reversal
transaction is a reversal
50 Unassigned
a device completed a transaction but the
Site Controller does not have a record of it
52
Gate
transaction was started at a gate controller
54 Aborted
transaction was aborted (pump was
deactivated) before pumping was
completed
55 Delivery
transaction is a fuel delivery, either
manually entered at the card reader
terminal or registered by a tank monitor
71 Manual
transaction was manually entered at the
card reader terminal***
77
Pulse err
caused by dual pulser failure
78 Prod
out
pump reports it is out of this type of
product
79
Pump down
a pump is not working**
81
Withdrawal
transaction was a cash withdrawal**
*The message printed in the Error field of the
transaction printout.
**Site Controller II only.
***Site Controller I only.
Site-Host Mode
Standard log in—an example of the sign-on
command and response with calculated CRC-16
check sums:
10,
PC/Site Control
Required Settings
for SC II
Network Poll Address = 1.
Site ID = site ID in PC password file.
Password for user 1 is identical in PC password file.
Baud rate correct for modem and its switches.
Command Line Options
SC [/Aargument] [/Bbaud] [/Ccom#] [/Dphone] [/L]
[/Ttimeout] [siteid]
/Aargument Specify an argument to be passed to a
file of Site Controller commands that is used as input
to PC/SiteControl. Multiple arguments can be sent
using multiple /A options. /A options must come
before any other parameters.
/Bbaud 300, 1200, 2400, or 9600; default is 1200
/Ccom# 1 or 2; default is 1
/Dphone Specify the phone number to dial to
connect to a Site Controller. Use this option only if
you connect to the Site Controller through a dial-out
modem and you want to override the number in the
password file. P requests pulse (rotary) dialing, T
requests touch dialing, and a comma requests the
modem to pause 2 seconds in the dialing sequence to
wait for a second dial tone.
Another phone number option is the modem timeout
length. That is the time the modem will wait for an
answer. The modem timeout length is the number of
seconds surrounded with square brackets [], typed
after the /D.
/L Output usually appears on the screen. This
option will make the output also print on the PC
printer.
/Ttimeout Specify how long to wait for a response
from the Site Controller. The time is specified in
eighteenths of a second (18 = 1 second); default and
shortest timeout allowed is 3 (0.167 seconds).
siteid Specify the site ID number. Use this option
only for sites you are dialing up with a modem, not
for direct-connect sites. Use an asterisk (*) as the site
ID to call all the sites in the password file.
Input and Output
Redirection
If you use site-control mode, the input and output
files will be on the PC’s disk, instead of the Site
Controller’s disk. Similarly, printed output will be
printed on the PC’s printer, instead of the Site
Controller’s printer.