beautypg.com

Raw mode error codes, Console, Card & gate reader – Gasboy CFN Series CFN II Quick Reference User Manual

Page 24: Pump control unit, Tank monitor

background image

CFN II Quick Reference

20

C09159 Rev. 2238

Console

Errors in console-to-Site Controller messages:

CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—card read error

Errors in Site Controller-to-console messages:

NB3—buffer busy
NB5—invalid command
NB7—receiver overrun
NBA—bad cyclical redundancy check (CRC)

Card & Gate Reader

Errors in reader-to-Site Controller messages:

CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—read error

Errors in Site Controller-to-reader messages:

NB3—buffer in use
NB4—not hexadecimal
NB5—invalid command
NB6—undefined EE command number
NB7—overflow/framing error
NB8—input buffer overrun
NB9—alphanumeric display busy
NBA—bad cyclical redundancy check (CRC)

Pump Control Unit

Errors in PCU-to-Site Controller messages:

CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response

Errors in Site Controller-to-PCU messages:

NB0—invalid hose number or price level
NB1—pump in use
NB2—transaction data unavailable
NB4—not hexadecimal
NB5—invalid command
NB6—invalid pump number
NB7—overrun
NB8—buffer overflow
NB9—test
NBA—bad cyclical redundancy check (CRC)
NBD—power failure
NBE—RAM contains transaction data

Tank Monitor

CRC—bad cyclical redundancy check (CRC)
DIE—number of communication losses
NOR—no response
Fuel Point Reader

Errors in FPR-to-Site Controller messages:

CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors

Errors in Site Controller-to-FPR messages:

NB4—not hexadecimal
NB5—invalid command
NB7—receiver overrun
NB8—input buffer overrun

Raw Mode Error

Codes

The following error codes may appear in conjunction
with the %E error variable.

Code

Meaning

Code

Meaning

00

Completed, Ok, Passed

15

Valid card, bit mapped

01 Transaction(s)

in

progress

16

Valid card, limited

02

Not found or does not

exist

17

Invalid card, bit mapped

03 Invalid

data

18 Invalid

card,

limited

04

Card is valid

19

Expecting NC, NW, or

NY

05

Card is not valid

20

String too long

06

Device out of service

21

Print heading before

record

07

Pump is in use

22

Some valid, some not

08

Pump is not on

23

Already exists

09 Illegal

command

24 Invalid

price

10

Command failed

25

Can’t open file

11

No more file space

26

Site not stopped

12

Manager key required

27

Can’t activate

13 Site

is

stopped

28 Gate

in

use

14 Invalid

option