Raw mode error codes, Console, Card & gate reader – Gasboy CFN Series CFN II Quick Reference User Manual
Page 24: Pump control unit, Tank monitor

CFN II Quick Reference
20
C09159 Rev. 2238
Console
Errors in console-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—card read error
Errors in Site Controller-to-console messages:
NB3—buffer busy
NB5—invalid command
NB7—receiver overrun
NBA—bad cyclical redundancy check (CRC)
Card & Gate Reader
Errors in reader-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—read error
Errors in Site Controller-to-reader messages:
NB3—buffer in use
NB4—not hexadecimal
NB5—invalid command
NB6—undefined EE command number
NB7—overflow/framing error
NB8—input buffer overrun
NB9—alphanumeric display busy
NBA—bad cyclical redundancy check (CRC)
Pump Control Unit
Errors in PCU-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
Errors in Site Controller-to-PCU messages:
NB0—invalid hose number or price level
NB1—pump in use
NB2—transaction data unavailable
NB4—not hexadecimal
NB5—invalid command
NB6—invalid pump number
NB7—overrun
NB8—buffer overflow
NB9—test
NBA—bad cyclical redundancy check (CRC)
NBD—power failure
NBE—RAM contains transaction data
Tank Monitor
CRC—bad cyclical redundancy check (CRC)
DIE—number of communication losses
NOR—no response
Fuel Point Reader
Errors in FPR-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
Errors in Site Controller-to-FPR messages:
NB4—not hexadecimal
NB5—invalid command
NB7—receiver overrun
NB8—input buffer overrun
Raw Mode Error
Codes
The following error codes may appear in conjunction
with the %E error variable.
Code
Meaning
Code
Meaning
00
Completed, Ok, Passed
15
Valid card, bit mapped
01 Transaction(s)
in
progress
16
Valid card, limited
02
Not found or does not
exist
17
Invalid card, bit mapped
03 Invalid
data
18 Invalid
card,
limited
04
Card is valid
19
Expecting NC, NW, or
NY
05
Card is not valid
20
String too long
06
Device out of service
21
Print heading before
record
07
Pump is in use
22
Some valid, some not
08
Pump is not on
23
Already exists
09 Illegal
command
24 Invalid
price
10
Command failed
25
Can’t open file
11
No more file space
26
Site not stopped
12
Manager key required
27
Can’t activate
13 Site
is
stopped
28 Gate
in
use
14 Invalid
option