23 — Wayne 3 product blender, hoses 1, 3, and 5.
For Wayne products V580 and V590U. Previously
these pumps required using 5 hoses, setting the price
code for hoses 2 & 4 to 99. With this option, only
define 3 hoses and the Wayne driver maps to the
appropriate pump positions automatically.
Tokheim Pump Programming
Mode 19 - set dispenser function code to 0.
Mode 23 - set address (1-16), number of products,
number of sides, and number of prices.
Mode 25 - set price-change mode equal to 1.
Mode 26 - on the Premier should be set as 1.
Site Controller II K2 Jumper Settings
In the Site Controller II section (earlier in this
manual) see the jumper drawings under CPU Board.
Gilbarco Interface Unit
Part number: C05688. Use a C04500 cable from the
RS422/RS485 junction box to the RS422 port of the
interface unit.
Use Gilbarco firmware version 70.2 or later. Product
authorization does not work with Gilbarco pumps
before version 2.0c of Gasboy’s interface firmware
and version 2.0cp2 of the Site Controller II software.
Interface
Terminal
Short
Wire
Color
Terminal Block
Connection
Field
Wire
Color
Gilbarco
dist. Box
Terminal
Legend
P1-1
red
1+ (top terminal) black box
1
-BLK
P1-2
black
1- (next down)
red
box 1
+RED
P2-1
red
2+
(third
down) black box
2
-
BLK
P2-2
black
2- (bottom)
red
box 2
+ RED
CPU Board
Jumper
Function and/or Normal Setting
K1
All K1 jumpers are absent.
K2
All K2 jumpers are absent.
K3
Position 1: enables the dead man timer.
K3-1 jumper must be installed.
K3-1 is the pair of K3 terminals closest to P9, the
long double-row offboard connector at the edge
of the board.
Position 2: K3-2 jumper is absent. K3-2 is the
pair of K3 terminals farthest from P9.
K4 ----
K5
Battery to U31; must install.
K6
Battery to U32; must install.
K7
Enables the AC power fail circuit; must install.
K8
K8 jumper is absent.
DIP Switch Bank 2. This switch sets the poll address
and allows memory to be cleared.
Position & Definition
Setting(*=customary)
1 debug
mode
*closed=normal mode
open=debug mode
2
erase memory on reset
*closed=no
open=yes
3-8
interface address
see next table
Address
2-3
2-4
2-5
2-6
2-7
2-8
1 cl cl cl cl cl cl
2 cl cl cl cl cl op
3 cl cl cl cl op cl
4 cl cl cl cl op op
5 cl cl cl op cl cl
.
.
.
64 op op op op op op
DIP Switch Bank 3
Position & Definition
Setting(*=customary)
1-2
local terminal baud rate
*open=9600
(also see below)
3
CRIND
open=RS-422 to CRIND
closed=current loop
4
reports (see below)
open=onhook activate
closed=no report
5
product authorization
open= no restrictions
closed=restrict grades
Switch 3-4: with Site Controller versions before 2.0b,
pumps are deactivated if offhook, and activated if
onhook. This is the sequence reported with push-to-
start and cash-credit.
Baud Rate
3-1
3-2
9600 open open
2400 open closed
1200 closed open
300 closed
closed
DIP Switch Bank 4. This switch selects certain price
level options and allows either twelve or sixteen
pumps (six or eight double-sided units) on a loop.