Crind, Jumpers, Keypad – Gasboy CFN Series CFN II Quick Reference User Manual
Page 41: Cabling

CFN II Quick Reference
C09159 Rev. 2238
37
Jumpers
2-wire operation (default): jumpers 9, 10, and 11 in
position 1.
Connector J4:
3 - Tx+/Rx+ (CFN 422 - 1 & 3)
4 - Tx-/Rx- (CFN 422 - 2 & 4)
4-wire operation: jumper 9 - position 1; jumpers 10
and 11 - position 2.
Connector J11:
3 - Rx- (CFN422-4)
4 - Rx+ (CFN422-3)
5 - Tx+ (CFN422-1)
6 - Tx- (CFN 422-2)
CRIND
Version 2.0b or later of the Site Controller software
is required to run a Gilbarco CRIND (Card Reader IN
Dispenser). The CRIND should be on the RS-422
port of the current loop driver.
Keypad
The keys on the CRIND keypad can be configured
for different functions with the Tokheim
DPT/Gilbarco CRIND keyboard layout item on page
4 of the SC II’s SYS_PAR program. The characters
that select different functions are shown below. Note
that these characters are case-sensitive:
Character Function
0-9
Numeric digits 0 through 9
. Decimal
point
E ENTER
C CLEAR
Y Yes
N No
$ Cash
inside
c Cash
outside
D Debit
inside
d Debit
outside
B
Credit (bank card) inside
b Credit
outside
X CANCEL
x
CLEAR/CANCEL (CLEAR if data
entry started; else CANCEL)
H Help
h
Help/Decimal (Decimal if data
entry started; else Help)
n
No/CANCEL (No if in yes/no
state; else CANCEL)
S Start
u unused
key
The numbers of the keypad keys on the CRIND are:
1 2 3 4 5
6 7 8 9 10
11 12 13 14 15
16 17 18 19 20
Note that keys on the left half of the keyboard—that
is, 1, 2, 3, 6, 7, 8, 11, 12, 13, 16, 17, and 18—cannot
be programmed.
The default function arrangement of the CRIND
keypad is:
1 2 3 u b
4 5 6 $ B
7 8 9 N Y
C 0 E H X
The string that would be typed into the Tokheim
DPT/ Gilbarco CRIND keyboard layout item in
SYS_PAR to give the CRIND keypad function
arrangement shown above is:
123ub456$B789NYC0EHX
Cabling
D-Box to Gilbarco Interface
Pump Loop
Part number: C06691.
There are two wires, which have spade lugs on one
end and a DB-9S connector on the other. The wires
connect the terminal block on the back of the
interface box to the male 9-pin connector current
loop at the distribution box.
Terminal Block
DB-9S
Wire Color
1 -
6
red
1 +
7
black
At the terminal block, connect the red wire to the
black wire and the black wire to the red wire.
CRIND Loop
Part number: adaptor is C06692; cable is C06242;
both together are C06326.
There are four wires, which have a modular handset