9800 pump dispenser, Cpu board, Jumpers – Gasboy CFN Series CFN II Quick Reference User Manual
Page 45: Led indicators, Test points, Switches

CFN II Quick Reference
C09159 Rev. 2238
41
9800 Pump
Dispenser
CPU Board
Jumpers
Jumper K1 is set according to the size of the RAM IC
in socket U19. At this time, only the 2K size is being
used:
RAM
Jumper Pins
2K
across 2 and 3
8K
across 1 and 2
LED Indicators
LED
Function
L1
AUTH1 - side 1 AC authorization present
L2
SLOW1 - side 1 slow flow solenoid
L3
FAST1 - side 1 fast flow solenoid
L4
SUBM1 - side 1 submersible starter relay
L5
AUTH2 - side 2 AC authorization present
L6
SLOW2 - side 2 slow flow solenoid
L7
FAST2 - side 2 fast flow solenoid
L8
SUBM2 - side 2 submersible starter relay
L9
PUL1A - side 1 pulser, channel A
L10
PUL1B - side 1 pulser, channel B
L11
HAND1 - side 1 handle switch
L12
PUL2A - side 2 pulser, channel A
L13
PUL2B - side 2 pulser, channel B
L14
HAND2 - side 2 handle switch
Test Points
Test points are provided for voltage measurements.
Test Point
Function
TP1 +5VDC
TP2 DC
ground
Switches
Switch settings should be changed with the power
switch OFF. The new settings are read by the CPU
board when the power is turned ON again.
Switch Bank 1
Position & Definition
Setting(*=customary)
1 baud
rate
*open=9600
closed=1200
2 communication
mode
*open=on-line
closed =standalone
3-4
lead detect delay
see below
5 ----
6 authorization
activates
*open=no
closed=yes
7 totalizers
*open=no
closed=reset
8 ----
Delay Time
1-3
1-4
0 closed
closed
4 closed
open
5 open
closed
6 open
open
Switch Bank 2
This bank serves two purposes:
•
address setting when communicating on the
Gasboy RS-485/RS-422 loop, or
•
pulser output rate selector when pulser data is
sent to a fuel management system other than
Gasboy.
Address
2-1
2-2
2-3
2-4
1 cl cl cl
cl
2 op cl cl cl
3 cl op cl cl
4 op op cl cl
5 cl cl op
cl
6 op cl op
cl
7 cl op op
cl
8 op op op cl
9 cl cl cl
op
10 op cl cl op
11 cl op cl
op
12 op op cl op
13 cl cl op
op
14 op cl op
op
15 cl op op
op
16 op op op
op